Split air conditioning 1x1 Daikin Sensira TXF60F · 5,160 frigories; set and technical information, range illustration — Uniclima

Daikin TXF60F split air conditioning unit

To air condition a room with a wall-mounted split: 5,160 frigories/h (6 kW) nominal in cooling.

kcal/h
≈ 5.160
Refrigerant
R32

Description

To climate control a room with a wall-mounted split: 5,160 frigories/h (6 kW) nominal cooling capacity. Daikin TXF60F includes one indoor unit and one outdoor unit; it is not a system for distributing cooling independently between multiple rooms. Check the load of the room and the installation space before choosing. Installation not included.

The choice of power depends on the space, its orientation, and its insulation. A split unit located in one room does not guarantee the same temperature in adjacent rooms; to serve multiple rooms, it is advisable to consider a multisplit system or a ducted installation.

Wi-Fi is included to manage the equipment from the manufacturer's compatible application.

Components and supply

What does Daikin TXF60F include?

Indoor unit, outdoor unit, and control of the indicated set.

ModelComponentSupply scope
FTXF60FIndoor unit
1 included
RXF60D9Outdoor unit
1 included
ARC470A1Infrared remote control included
1 included

Include the infrared remote control ARC470A1.

Illustrative cover of the range, without scale. Individual images of the family with visual adjustment of color and lighting. The design of the control may vary due to catalog updates.

Guide

What to check before installing Daikin TXF60F?

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Check the internal space (990 × 295 × 263 mm) and external space (870 × 734 × 373 mm) plus the clearances from the manual.
  2. Refrigerant line 1/4″ / 1/2″; run up to 30 m and elevation up to 20 m. Pre-charge for 10 m; check the additional charge in the manual.
  3. The nominal power guides the selection; the thermal load calculation and installation are carried out separately.
Technical data

Technical sheet: Daikin TXF60F

Brand
Daikin
Model and composition
Daikin TXF60F
Supply scope
FTXF60F + RXF60D9 + ARC470A1
Installation
Not included
Availability and transport
In stock. VAT and shipping to mainland Spain included. Installation not included.

Installation at a glance

Interior
990 × 295 × 263 mm width × height × depth
Exterior
870 × 734 × 373 mm width × height × depth
Indoor unit
FTXF60F
Pipe · liquid / gas
1/4″ / 1/2″
Acceptable travel distance
3 m–30 m
Maximum slope
20 m
Factory published load
1.15 kg
Length covered by precharge
10 m
Additional load
20 g/m above 10 m Check the manual of the provided revision.
Manufacturer's documentation

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this set. The testing conditions and climate are part of each value.

Set
TXF60F
Identification and control
Indoor unit
FTXF60F
Identification and control
Outdoor unit
RXF60D9
Identification and control
Type
1×1 split wall-mounted unit · cooling and heating
Identification and control
Published supply
220 V · single-phase
Identification and control
Infrared remote control
ARC470A1
Identification and control · The design of the control may vary due to catalog updates.
Connectivity
Wi-Fi control with the Onecta app included.
Identification and control · Daikin Spain · tariff update 2025 · PDF page 15.
Nominal power in cold conditions
6.00 kW
Power and efficiency
approximate nominal cooling capacity
5,160 frigories/h
Power and efficiency · Indicative conversion: kW × 860.
Nominal heat output
6.40 kW
Power and efficiency
Energy class in cold
A++
Power and efficiency
Energy class in heating
A+ · average climate
Power and efficiency
SEER
6,15
Power and efficiency
SCOP · average climate
4,06
Power and efficiency
Interior · width × height × depth
990 × 295 × 263 mm
Dimensions and sound
Exterior · width × height × depth
870 × 734 × 373 mm
Dimensions and sound
Internal weight
13.5 kg
Dimensions and sound
External weight
50 kg
Dimensions and sound
Interior sound pressure in silent mode
33 dB(A)
Dimensions and sound · Sound pressure level, not sound power.
Pipe · liquid / gas
1/4″ / 1/2″
Pipe and refrigerant
Acceptable travel distance
3 m–30 m
Pipe and refrigerant
Maximum slope
20 m
Pipe and refrigerant
Refrigerant
R32
Pipe and refrigerant
Factory published load
1.15 kg
Pipe and refrigerant
Length covered by precharge
10 m
Pipe and refrigerant
Additional load
20 g/m above 10 m
Piping and refrigerant · Check the manual provided for the review.
Cooling
1850 W
Nominal electrical consumption · Nominal electrical power, not thermal capacity.
Heating
1630 W
Nominal electrical consumption · Nominal electrical power, not thermal capacity.
Cooling
342 kWh/year
Annual reference consumption
Heating · average climate
1,654 kWh/year
Annual reference consumption
Residential use
3 years
Daikin warranty · According to the manufacturer's conditions.
Other uses
2 years of material replacement
Daikin warranty · Check the scope and exclusions in the Daikin terms and conditions.
Before purchasing
  • Daikin Spain, tariff update 2025, PDF page 15. Nominal testing capacities; dimensions in width × height × depth.

Documentation

Frequently asked questions

Questions about Daikin TXF60F

How many frigories does it have and how many rooms is it suitable for?
This unit has a nominal cooling capacity of 5,160 frigories/h (6 kW) and a single indoor unit (FTXF60F). It is designed for a room or an open space that has been sized as such. It does not equate to a 2x1 for two closed rooms.
Is it an option if I am looking for an air conditioning unit with 5,000 frigories?
The exact figure for this combination is approximately 5,160 kcal/h nominal (6 kW), above 5,000. If the calculation for your room requires at least 5,000 kcal/h, also compare the capacity at the expected outdoor temperature and the margin indicated by the installer.
Is it suitable for a bedroom with a lot of sunlight?
It can be useful, but it's important to know how much your bedroom heats up, especially if it gets afternoon sun or is under the roof. If you need a bit more power, compare the Daikin TXF71FIt goes from about 5,160 to 6,106 frigories/h. Tell us the meters and if the ceiling is insulated: we help you choose the power and check the noise of the split for sleeping.
How do I know if it has enough power for my living room?
To choose the power, you need to consider the size of the living room, how much sunlight it receives, and the insulation. If the living room is spacious or continues to retain a lot of heat, compare the Daikin TXF71FIt goes from about 5,160 to 6,106 frigories/h. Tell us the meters and how much sun it receives, and we will help you choose.
What noise will I have to compare to use it at night?
The technical sheet of FTXF60F states 33 dB(A) of indoor sound pressure in cold conditions. Compare the speed and testing conditions: the lowest value does not describe the noise at full power nor guarantees that level measured in your bed. Do not confuse it with sound power.
What units are included?
It is the set 1×1 with interior FTXF60F and exterior RXF60D9. The inspection of the outdoor unit is confirmed upon delivery.
What pipe do you need?
Liquid and gas: 1/4″ / 1/2″. The maximum published distance is 30 m; the installation requires checking the exact manual.
Is the installation included?
No. Piping, supports, installation, and commissioning are valued separately.

Services for your air conditioning