Hisense cassette air conditioning set ACT52UR4RCC8 + AUW52U4RS7, 4,300 kcal/h — Uniclima

Hisense cassette air conditioning ACT52UR4RCC8 + AUW52U4RS7 · Single-phase

To air condition an open area from the ceiling: Hisense cassette ACT52UR4RCC8 + AUW52U4RS7 with a nominal cooling capacity of 4,300 frigories/h (5 kW).

kcal/h
≈ 4.300
Refrigerant
R32

Description

To air condition an open area from the ceiling: Hisense cassette ACT52UR4RCC8 + AUW52U4RS7 with a nominal cooling capacity of 4,300 frigories/h (5 kW). It is an alternative to consider when there is a false ceiling and you want to free up the walls; it does not replace multiple splits for closed rooms. Check height, mounting space, and air distribution. Installation not included.

Before choosing it, it is advisable to check the available height above the ceiling and the location of the equipment. The panel and the control are part of the configuration: in "What is included" you can see which ones are supplied with this reference.

Wi-Fi control is optional and requires an accessory that is purchased separately.

Components and supply

What is included in Hisense ACT52UR4RCC8 + AUW52U4RS7?

Exact combination documented by Hisense: ACT52UR4RCC8 + AUW52U4RS7.

ModelComponentSupply scope
ACT52UR4RCC8Cassette indoor unit
570 × 215 × 570 mm
1 included
AUW52U4RS7Outdoor unit
810 × 580 × 280 mm
1 included
PE-QEA-LDDecorative panel
620 × 40 × 620 mm
1 included
Wireless remote controlEquipment control
The image shows the control of the range. The design may vary due to catalog updates.
1 included

Installation, pipes, supports, and construction materials not included.

Illustrative composition of the range, not to scale. The design of the control may vary due to catalog updates.

Guide

What to check before installing Hisense ACT52UR4RCC8 + AUW52U4RS7

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Check the dimensions and leave access for connections, filter cleaning, and condensate pump maintenance.
  2. The installer must calculate the thermal load and check the air distribution and drainage.
  3. Check the 1/4″ / 1/2″ pipes, the slope, and the single-phase power supply before installation.
Technical data

Technical sheet: Hisense ACT52UR4RCC8 + AUW52U4RS7

Brand
Hisense
Model and composition
Hisense ACT52UR4RCC8 + AUW52U4RS7
Supply scope
Indoor unit, outdoor unit, panel, and wireless remote control.
Installation
Not included
Availability and transport
Price including VAT. Installation not included. Not shipped to islands, Ceuta, Melilla, or abroad.

Installation at a glance

Interior
570 × 215 × 570 mm width × height × depth
Exterior
810 × 580 × 280 mm width × height × depth
Factory published load
1.08 kg Hisense Spain catalog
Pipe · liquid / gas
1/4″ / 1/2″
Maximum length
40 m
Maximum slope
30 m
Length covered by precharge
5 m
Additional load
15 g/m Based on the preloaded length
Power supply
Single-phase · 220–240 V · 50/60 Hz
Manufacturer's documentation

Specifications and dimensions of the model

Capabilities, consumption, efficiency, noise, and dimensions of this set. The testing conditions and climate are part of each value.

Nominal cooling of the unit
5.00 kW
Power and efficiency of the system
Nominal heat of the assembly
5.50 kW
Power and efficiency of the system
kcal/h
≈ 4.300
Power and efficiency of the system · Conversion of nominal capacity in cooling: kW × 860
SEER / SCOP
6,40 / 4,10
Power and efficiency of the system · SCOP in moderate climate
Cold efficiency
A++
Power and efficiency of the system
Nominal consumption in cold / heat
1.47 / 1.48 kW
Power and efficiency of the system · Absorbed electrical power
Interior · width × height × depth
570 × 215 × 570 mm
Dimensions, sound and flow · Body without panel
Exterior · width × height × depth
810 × 580 × 280 mm
Dimensions, sound and flow rate
Panel · width × height × depth
620 × 40 × 620 mm
Dimensions, sound and flow rate · PE-QEA-LD
Net weight indoor unit
15.5 kg
Dimensions, sound and flow · Without panel
Interior sound pressure
42 / 38 / 34 dB(A)
Dimensions, sound and flow · High / medium / low
Indoor air flow
700 / 600 / 510 m³/h
Dimensions, sound and flow · High / medium / low
Refrigerant
R32
Installation and refrigerant
Factory published load
1.08 kg
Installation and refrigerant · Hisense Spain Catalog
Pipe · liquid / gas
1/4″ / 1/2″
Installation and refrigerant
Maximum length
40 m
Installation and refrigerant
Maximum slope
30 m
Installation and refrigerant
Length covered by precharge
5 m
Installation and refrigerant
Additional load
15 g/m
Installation and refrigerant · Based on the pre-charged length
Power supply
Single-phase · 220–240 V · 50/60 Hz
Installation and refrigerant
Wi-Fi
Optional
Installation and refrigerant · Adapter not included
Condensate pump
Included
Installation and refrigerant
Warranty
3 years
Installation and refrigerant · According to Hisense conditions and applicable use
Before purchasing
  • Exact combination data in the Hisense documentation. Please refer to the installation manual of the supplied revision.

Documentation

Frequently asked questions

Questions about Hisense ACT52UR4RCC8 + AUW52U4RS7

How many frigories does this cassette have?
The Hisense ACT52UR4RCC8 + AUW52U4RS7 set has a nominal cooling capacity of 4,300 frigories/h (5 kW). The power refers to the complete set, not to each air outlet of the cassette.
Is a cassette better than a wall-mounted split for my living room or premises?
This cassette is an option if the space and the false ceiling allow for the installation of ACT52UR4RCC8 and proper air distribution. It offers 5 kW nominal cooling; it is not inherently better than a wall-mounted unit. To choose, compare the thermal load, height, the position of people, and the installation cost.
Does it cool several closed rooms?
It should not be chosen for that purpose just because it has 4,300 frigories/h. An interior cassette distributes air in the area where it is installed; doors and partitions limit access to other rooms. For closed spaces, consider a multisplit or a duct network designed for them.
What should I check if the space receives a lot of sunlight?
Take into account the square meters of the space, the windows, and the hours of sunlight. This cassette has about 4,300 frigories/h; to determine if it is sufficient, we need to understand the characteristics of the space. Before making a decision, we will review the power and the available space in the false ceiling with you.
What units are included?
ACT52UR4RCC8 + AUW52U4RS7. Indoor unit, outdoor unit, panel, and wireless remote control.
Does it include Wi-Fi and installation?
No. The Wi-Fi requires an optional adapter and the installation is quoted separately.
What power supply does it need?
This combination is single-phase. The external reference is AUW52U4RS7.

Services for your air conditioning

Hisense cassette air conditioning ACT52UR4RCC8 + AUW52U4RS7 · Single-phase