3 years Domestic use TCL M42S1S2 cassette air conditioning
To air condition an open area from the ceiling: cassette TCL M42S1S2 with 10,406 frigories/h (12.1 kW) nominal cooling capacity.
- Pipe
- 3/8″ / 5/8″
- Wi-Fi
- Yes, included.
- kcal/h
- ≈ 10.406
- Refrigerant
- R32
Description
To air condition an open area from the ceiling: cassette TCL M42S1S2 with 10,406 frigories/h (12.1 kW) nominal cooling capacity. It is an alternative to consider when there is a false ceiling and you want to free up the walls; it does not replace several splits for closed rooms. Check height, mounting space, and air distribution. Installation is separate.
Before choosing it, it is advisable to check the available height above the ceiling and the location of the equipment. The panel and the control are part of the configuration: in "What is included" you can see which ones are supplied with this reference.
Wi-Fi is included to manage the equipment from the manufacturer's compatible application.
What does TCL M42S1S2 include?
Cassette Set 1×1: components grouped according to the TCL table.
| Model | Component | Supply scope |
|---|---|---|
| MN42SS2 | Cassette indoor unit | 1 included |
| MT4212 | Outdoor unit 910 × 804 × 378 mm | 1 included |
| NPAN90S1 | Cassette panel 950 × 45 × 950 mm · width × height × depth | 1 included |
It includes a wireless remote control and wall control as per the documented supply of this set. Installation, piping, supports, wiring, and commissioning are budgeted separately.
Illustrative images of the range, not to scale. The indicated measurements correspond to this set; the appearance may vary depending on the supplied revision. Indicative image of the control. Its design may vary due to updates in the TCL catalog.
What to check before installing TCL M42S1S2
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Check the cassette body and the NPAN90S1 panel separately. The dimensions of the panel do not match the ceiling cutout; ensure access to drainage and maintenance.
- 3/8″ / 5/8″ pipe. Precharge for 5 m; maximum equivalent length 75 m and height difference 30 m. Above 5 m: 25 g/m additional. The installer must check the PCB and review before intervening.
- The set is single-phase. The installer will check the voltage of the PCB, the protections, the wiring, and the ventilation distances.
- Wireless remote control and wall control included as per documented supply.
TCL M42S1S2
- Brand
- TCL
- Model and composition
- TCL M42S1S2
- Supply scope
- MN42SS2 + MT4212 set, with wireless and wall panel controls.
- Installation
- Not included
- Availability and transport
- In stock. VAT and shipping to mainland Spain included. Installation not included.
Installation at a glance
- Exterior
- 910 × 804 × 378 mm width × height × depth
- Pipe
- 3/8″ · 5/8″ liquid · gas
- Maximum equivalent length
- 75 m
- Maximum slope
- 30 m
- Precharge up to
- 5 m
- Factory charge · R32
- Consult PCB
- Additional load
- 25 g/m above 5 m
Load calculation and documentation
Outdoor unit: MT4212; factory load discrepancy between documents, check the PCB. Verify the PCB and inspection.
Additional load: 25 × (L − 5) g, only above 5 m and within the maximum travel.
L is the length of the run between the interior and exterior, not the sum of both pipes. The published limit is for equivalent length; fittings must be considered according to the manual. Outer diameters of refrigerant piping in liquid / gas order.
Check the PCB, review, and manual. Installation and handling of refrigerant by a qualified professional; do not add gas only due to lack of cooling.
Specifications and dimensions of the model
Capabilities, consumption, efficiency, noise, and dimensions of this set. The testing conditions and climate are part of each value.
- Set
- M42S1S2
Set and power supply - Indoor unit
- MN42SS2
Set and power supply - Outdoor unit
- MT4212
Set and power supply - Type
- 1×1 cassette · cooling and heating
Set and power supply - Power supply
- 220 V · single-phase
Set and power supply - Nominal power in cold conditions
- 12.10 kW
Power and efficiency · Technical catalog TCL 2025–2026. Assembly and components: PDF page 34 (printed 33). - Approximate nominal cooling capacity
- 10,406 kcal/h
Power and efficiency · Conversion: kW × 860. - Nominal heat output
- 13.50 kW
Power and efficiency · Technical catalog TCL 2025–2026. Assembly and components: PDF page 34 (printed 33). - Energy class in cold
- A++
Power and efficiency - Energy class in heating
- A+
Power and efficiency - Body · published dimensions
- Height to be confirmed
Measures to prepare the installation · Catalog: body height of 245 mm; TCL website: 290 mm. Confirm the plan and review before sizing the false ceiling. - Exterior · width × height × depth
- 910 × 804 × 378 mm
Measures to prepare the installation - Net internal weight
- To be confirmed
Measures to prepare the installation · Catalog: 26.0 kg. TCL website: 28 kg. Discrepant documents; confirm the control board of the supplied unit before ordering. - Net external weight
- To be confirmed
Measures to prepare the installation · Catalog: 55 kg. TCL website: 54 kg. Discrepant documents; confirm the control board of the supplied unit before ordering. - Panel
- NPAN90S1
Measures to prepare the installation - Panel · width × height × depth
- 950 × 45 × 950 mm
Measures to prepare the installation · This does not correspond to the cut-out dimensions. The S series technical sheet states 950 × 950 × 45 mm in width × depth × height order. - Pipe · liquid / gas
- 3/8″ / 5/8″
Pipe and refrigerant · Technical catalog TCL 2025–2026. Assembly and components: PDF page 34 (printed 33). - Refrigerant
- R32
Pipe and refrigerant - Factory published load
- According to the PCB
Pipe and refrigerant · Catalog: 2.20 kg; TCL website: 1.80 kg. Do not use any of these values as a refill order without checking the exact PCB and manual. - SEER
- 6,1
Efficiency, consumption, and air circulation - SCOP · average climate
- 4
Efficiency, consumption, and air circulation - Nominal consumption in cold
- 4240 W
Efficiency, consumption, and air circulation · Nominal electrical power, not thermal capacity. - Nominal heat consumption
- 3700 W
Efficiency, consumption, and air circulation · Nominal electrical power, not thermal capacity. - External sound power
- 68 dB(A)
Efficiency, consumption, and air circulation · Sound power, not sound pressure. - Interior sound power · S/H/M/L/silence
- 64/61/60/58/54 dB(A)
Efficiency, consumption, and air circulation · Sound power, not sound pressure. - Indoor air flow
- 2100 m³/h
Efficiency, consumption, and air circulation - Pipe covered by the precharge
- 5 m
Limits for preparing the installation · TCL Catalog 2026 Portugal, PDF page 12; this is not the maximum distance. - Maximum equivalent length
- 75 m
Limits for preparing the installation · Official catalog TCL Italy 2026, PDF page 59. Equivalent length, not just straight pipe. - Maximum slope
- 30 m
Limits for preparing the installation · Between the indoor and outdoor units. - Recommended minimum length
- 3 m
Limits for preparing the installation · Official catalog TCL Italy 2026. - Additional load above 5 m
- 25 g/m
Limits for preparing the installation · Within the permitted limits. Confirm PCB and inspection; intervention by a qualified professional. - Wi-Fi
- Wi-Fi included
Control and connectivity · Wi-Fi included and control with TCL Home according to the official TCL 2026 catalog: indoor unit MN42SS2, EAN 8720568112541. The reference and the EAN match the component in the Spanish catalog. Please refer to the linked connectivity documentation. - Application
- TCL Home
Control and connectivity · Remote control via TCL Home; requires a network and configuration compatible with the manual. - TCL warranty
- 3 years for domestic use
Warranty and conditions · The extension to 5 years is not confirmed for this reference. Check the conditions in Documentation.
- Data from the linked documentation for the indicated reference. Check the PCB and the installation manual of the supplied revision before sizing openings, connections, or refrigerant charge. The images are not assembly drawings. Some dimensions, weights, or loads differ between the 2025–2026 catalog and the current TCL sheet. Confirm the revision and its drawing before preparing the installation. Interior height: 245 mm in the Spanish catalog and 290 mm on the TCL website. The published charge varies between 2.20 and 1.80 kg; confirm the drawing and PCB.