Cointra Superlative Supra 34C boiler
Condensing boiler · New equipmentCointra Superlative Supra 34C

Cointra Superlative Supra 34C boiler

Heating and hot water for everyday use, combined in a gas boiler.

Gas
Natural / propane Professional configuration
Wi-Fi
Optional Connect Smart WiFi
Heating
5.4–32.6 kW 50/30 °C
Domestic hot water flow rate
19.5 l/min ΔT 25 °C
Gas and Wi-Fi: compatibility and accessories

Gas and conversion: The manufacturer documents natural gas G20 and propane G31. It is necessary to verify the supply configuration and adapt the appliance to the gas of the installation. Compatibility with butane G30 is not offered without explicit documentation of this version. The conversion and commissioning are the responsibility of a qualified professional; they are not included in the purchase. Source 1 ↗ Source 2 ↗

Wi-Fi and supply: The Superlative Supra catalog features Connect Smart WiFi as an optional control accessory. The upgrade to class A+ is only announced for 28 C and 34 C, not for 24 C. It is not included as standard. Source 1 ↗ Source 2 ↗

Description

Cointra Superlative Supra 34 C combines home heating and hot water for taps and showers. When choosing it, both water usage and heating needs are important: a home with multiple showers running at the same time requires a different assessment.

Domestic hot water is prepared when you turn on the tap, without an integrated storage tank. It is important to check how many water points you will use at the same time and the available space to replace the boiler.

Guide for this modelDoes your boiler show an error?Cointra Superlative Supra 34CSee codes
Guide

What to check before installing this boiler

The choice of equipment does not replace the inspection of the installation by a qualified professional.

  1. Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
  2. Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
  3. Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
  4. Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data

Technical data of Cointra Superlative Supra 34C boiler

Brand
Cointra
Model
Cointra Superlative Supra 34C boiler
Status
New
Supply scope
The reference V0TPF7AWM identifies the boiler. The manufacturer's assembly with standard flue has the reference V16973. Installation not included.
Shipping
Included in mainland Spain. Please confirm the deadline.
Commercial reference
V0TPF7AWM

Specifications and dimensions of the model

Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.

Useful heating power (80/60 °C)
4.9–30 kW
Heating
Useful heating power (50/30 °C)
5.4–32.6 kW
Heating
Heating water content
4.3 l
Heating
Heating expansion vessel
10 l
Heating
Useful domestic hot water power
4.8–34 kW
Hot water
Domestic hot water flow rate (ΔT 25 °C)
19.5 l/min
Hot water
Domestic hot water demand profile
XXL
Hot water
Preparation of domestic hot water
Instantaneous, without domestic hot water accumulator
Hot water
Dimensions (height × width × depth)
700 × 420 × 320 mm
Dimensions and connections
Net weight
31 kg
Dimensions and connections
Gas supply
G20: 20 mbar; G31: 37 mbar
Dimensions and connections
Electrical supply
230 V / 50 Hz
Dimensions and connections
Absorbed electrical power
99 W
Dimensions and connections
Degree of protection
IPX4D
Dimensions and connections
NOx emissions class
6
Dimensions and connections
Manufacturer's sources

PDF and documentation of the model

Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.

The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.

Frequently asked questions

Frequently asked questions: V0TPF7AWM condensing boilers

Is it suitable for a 200 m² house?
It can be if the calculated thermal load and the emitters fit within its power range. For example, 200 m² with a calculated demand of 80 W/m² require 16 kW, which is within its 4.9–30 kW range at 80/60 °C. This is a calculation assumption, not a surface certified by Cointra; a smaller boiler could also meet that heating demand. The higher domestic hot water flow rate may be the reason to choose the 34 C.
Can it handle two showers simultaneously?
Two showers of 8 l/min add up to 16 l/min. The 19.5 l/min declared at ΔT 25 °C exceeds that consumption; for example, that temperature difference corresponds to going from 10 to 35 °C. At 40 °C from 10 °C, a thermal approximation gives 19.5 × 25/30 = 16.25 l/min, with very little margin. That second flow rate is an estimate, not a certified data: the actual flow rate of the showers, the network pressure, and the inlet temperature must be checked.
Does it have a 10-liter tank for hot water?
No. The 10 liters correspond to the heating expansion vessel, not to a water reserve for showering. The Supra 34 C provides instant domestic hot water; its Eco and Comfort modes do not turn it into a boiler with a storage tank.
What changes compared to the Superlative Supra 28 C?
At a ΔT of 25 °C, it goes from 16.1 to 19.5 l/min, an increase of 3.4 l/min. In heating at 80/60 °C, it rises from 24 to 30 kW maximum. It maintains a height of 700 mm and a width of 420 mm, but the depth increases from 250 to 320 mm and the weight from 27 to 31 kg. It should not be chosen without also checking the available space.
Does it fit in a 30 cm deep cabinet?
No: the body of the Supra 34 C has a depth of 320 mm, which is 32 cm, before adding the necessary clearances and connections. Its overall dimensions are 700 × 420 × 320 mm. The installer must check the maintenance space and the flue; the dimensions of the body are not the final installation opening dimensions.
Does it accept natural gas and propane?
The documentation identifies G20 at 20 mbar and G31 at 37 mbar. The specific configuration, gas adaptation when applicable, and commissioning must be carried out by authorized professionals. It is not assumed that a unit can be connected interchangeably to both gases without these checks.
Does the price include installation and shipping?
Includes VAT and shipping to mainland Spain. Installation and adaptations are valued separately. The reference V0TPF7AWM identifies the boiler. The manufacturer's set with standard flue has the reference V16973. Installation not included.
Shipping to the mainland included
New equipment
Separate installation
Informed purchase
Cointra Superlative Supra 34C boiler