Wolf CGB-2K 20 boiler
Heating and hot water for everyday use, combined in a gas boiler.
- Gas
- Natural gas Convertible to propane
- Wi-Fi
- Optional WOLF Link Home
- Heating
- 18.9 kW 80/60 °C
- Domestic hot water flow rate
- 10.3 l/min ΔT 30 K
Gas and Wi-Fi: compatibility and accessories
Gas and conversion: It accepts natural gas G20 and conversion to propane G31 through the manufacturer's adjustment procedure. Compatibility with butane G30 is not offered without explicit documentation for this version. The conversion and commissioning are the responsibility of a qualified professional; they are not included in the purchase. Source 1 ↗ Source 2 ↗ Source 3 ↗
Wi-Fi and supply: The CGB-2K documentation includes the LAN/WLAN module WOLF Link Home (ISM7i) as an accessory. It is not assumed to be included. The manual allows for natural gas or propane and excludes other LPG; professional adaptation is required. Source 1 ↗ Source 2 ↗ Source 3 ↗
Description
Wolf combines home heating and hot water for taps and showers. When choosing it, both water usage and heating needs are important: a home with multiple showers running at the same time requires a different assessment.
Domestic hot water is prepared when you turn on the tap, without an integrated storage tank. It is important to check how many water points you will use at the same time and the available space to replace the boiler.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data of Wolf CGB-2K 20 boiler
- Brand
- Wolf
- Model
- Wolf CGB-2K 20 boiler
- Status
- New
- Supply scope
- Boiler reference only. Control, connections, exhaust and installation to be confirmed.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
- Commercial reference
- 8615054
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Maximum useful power (80/60 °C)
- 18.9 kW
Heating - Maximum useful power (50/30 °C)
- 20.4 kW
Heating - Minimum power (80/60 °C, natural gas)
- 3.8 kW
Heating - Minimum power (80/60 °C, LPG G31)
- 6.8 kW
Heating - Maximum heating pressure
- 3 bar
Heating - Heating expansion vessel
- 10 l
Heating - Production of domestic hot water
- Instantaneous, without integrated domestic hot water accumulator
Hot water - Maximum useful power in domestic hot water
- 22.2 kW
Hot water - Specific flow rate of domestic hot water (ΔT 30 °C)
- 10.3 l/min
Hot water - Domestic hot water flow rate with factory limiter
- 2.0–6.5 l/min
Hot water - Adjustable domestic hot water temperature
- 45–65 °C
Hot water - Maximum domestic hot water pressure
- 10 bar
Hot water - Dimensions (height × width × depth)
- 790 × 440 × 378 mm
Dimensions and connections - Weight
- 35 kg
Dimensions and connections - Heating connections
- G 3/4 inches
Dimensions and connections - Domestic hot water connections
- G 3/4 inches
Dimensions and connections - Gas connection
- R 1/2 inch
Dimensions and connections - Concentric flue connection
- 60/100 mm
Dimensions and connections - Electrical supply
- 230 V / 50 Hz
Dimensions and connections - NOx emissions class
- 6
Efficiency and consumption - Standby power consumption
- 3 W
Efficiency and consumption - Maximum electrical consumption
- 63 W
Efficiency and consumption - Degree of protection
- IPX4D
Efficiency and consumption - Nominal ErP power (Prated)
- 19 kW
Efficiency and consumption - Heating energy class
- A
Efficiency and consumption - Seasonal heating efficiency
- 93 %
Efficiency and consumption - Domestic hot water load profile
- XL
Efficiency and consumption - Energy class of domestic hot water
- A
Efficiency and consumption - Efficiency of domestic hot water
- 85 %
Efficiency and consumption - Normalized annual heating consumption (QHE)
- 10568 kWh/year
Efficiency and consumption - Normalized annual fuel consumption in domestic hot water (AFC)
- 17 GJ/year
Efficiency and consumption - Sound power level indoors (LWA)
- 47 dB
Efficiency and consumption
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- CGB-2(K) technical brochurePDF · 32 pages · WolfView original on the manufacturer's website ↗
- Service instructions for the installer CGB-2/CGB-2KPDF · 108 pages · WolfView original on the manufacturer's website ↗
- Technical sheet: CGB-2K in accordance with Regulation (EU) 811/2013PDF · 2 pages · WolfView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.