Chaffoteaux Pigma Green 25 Fume Extractor Fan Fime PX118 019 07 Ref. 60001869

Chaffoteaux Pigma Green 25 Fume Extractor Fan Fime PX118 019 07 Ref. 60001869

Stock · 5 units

If your boiler does not ignite or gets blocked due to a fault in the flue gas evacuation, you may need the Chaffoteaux Pigma Green 25 Fime PX118 019 07 Flue Gas Extractor Fan. This part is responsible for evacuating combustion gases and creating the necessary draft for the boiler to start. When it fails, you may experience faults such as 6 12, which indicates an anomaly with the flue gas extractor, or 6 04, which signals low fan revolutions. This fan is compatible with boilers from the Pigma Green range, as well as some models from Alixia Green and Urbia Green. It is recommended to replace it upon noticing any of these symptoms.

VAT included

Compatibility

Chaffoteaux boilers compatible with reference 60001869

Extractor with reference 60001869. Five confirmed compatibilities: PIGMA GREEN 25 EU and PIGMA GREEN 25.

Proven compatibility

Boiler modelFamilyVerification
Chaffoteaux PIGMA GREEN 25 EUPigma GreenContrasted
Chaffoteaux PIGMA GREEN 25Pigma GreenContrasted
Chaffoteaux ALIXIA GREEN 24Alixia GreenContrasted
Chaffoteaux URBIA GREEN 25Urbia GreenContrasted
Chaffoteaux URBIA GREEN 35 EUUrbia GreenContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 60001869 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 60001869. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor 60001869 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler starts, you can hear the attempt, and then it shuts off immediately without igniting.

    Cause: If the extractor does not rotate at the required speed, the air pressure switch does not close and the system cuts off the ignition.

    Check if the fan spins as soon as you request ignition; a slow or irregular start points to it.

  • 02

    The extractor does not spin, it stays silent when trying to turn on.

    Cause: It could be a seized motor or a lack of electrical supply.

    Before replacing it, try to turn the shaft by hand with the boiler unplugged to rule out that it is simply stuck.

  • 03

    Loud noise, squeaking or noticeable vibration when the extractor is operating.

    Cause: They are typical symptoms of worn bearings or a dirty and unbalanced turbine.

    Check if the turbine has accumulated dirt on the blades before replacing the entire part.

  • 04

    The boiler is locking out with a fault indicating extraction or fan issues.

    Cause: The extractor does not reach the air pressure that the control unit requires to validate the combustion.

    First, rule out that the flue duct is blocked, as it causes the same blockage without the extractor failing.

Fault codes Chaffoteaux that this part resolves

CodeFaultDiagnosis and solution
6 12Fan error (no tachometer signal at start-up/flue gas extractor anomaly).The Fime PX118 fan does not deliver the tachometer signal or is faulty; check the power supply and tachometer return at the connector, confirm that it starts and spins freely, and compare rpm in the service menu.
6 04Low fan revolutions (insufficient speed or lack of tachometer signal in operation).The extractor does not reach the commanded speed or its rpm feedback is unstable; check for free rotation/friction of the impeller, measure rpm/feedback in the service menu, and verify voltage at the fan connector.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Chaffoteaux extractor 60001869

Catalogue reference
60001869
Brand
Chaffoteaux
Type of part
Extractor fans
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the extractor 60001869

For which models is the Chaffoteaux Pigma Green 25 ECPG25 flue gas extractor fan compatible?
It is compatible with the following models: PIGMA GREEN 25 EU, PIGMA GREEN 25, ALIXIA GREEN 24, URBIA GREEN 25, and URBIA GREEN 35 EU.
What fault codes are documented for this fan?
The documented fault codes are 6 12 and 6 04.
Is this extractor fan suitable for the Pigma Green range?
Yes, the Chaffoteaux Pigma Green 25 flue fan is suitable for the Pigma Green range.
How many models are compatible with this fan?
The Chaffoteaux Pigma Green 25 flue gas extractor fan is compatible with a total of 5 models.
What is the reference for this extractor fan?
The reference for this extractor fan is ECPG25.

Spare parts related to Chaffoteaux Pigma Green

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Chaffoteaux Pigma Green 25 Fume Extractor Fan Fime PX118 019 07 Ref. 60001869