Intergas Fan Flue Extractor Kombi Kompakt HR 28 24 Torin Sifan DSB144-22 Ref. 074507

Intergas Fan Flue Extractor Kombi Kompakt HR 28 24 Torin Sifan DSB144-22 Ref. 074507

Stock · 2 units

Intergas Kombi Kompakt HR 28 24 includes the Torin Sifan DSB144-22 Flue Extractor Fan, with reference 074507. This fan is responsible for expelling combustion gases and generating the necessary draft for the boiler to start. If it malfunctions, you will notice that the boiler does not ignite or locks out due to issues with flue gas evacuation, and fault code 8: Incorrect fan speed may appear. It is compatible with models such as HR 22, HR 28, HR 28/24, and HR 36/30, among others. It is recommended to replace it when the boiler shows the mentioned symptoms.

VAT included

Compatibility

Intergas boilers compatible with reference 074507

Extractor with reference 074507. 16 verified compatibilities: HRE 24/18 and HRE 28/24.

Proven compatibility

Boiler modelFamilyVerification
Intergas HRE 24/18Intergas Kombi Kompakt HREContrasted
Intergas HRE 28/24Intergas Kombi Kompakt HREContrasted
Intergas HRE 36/30Intergas Kombi Kompakt HREContrasted
Intergas HReco 24Intergas Kombi Kompakt HRecoContrasted
Intergas HReco 30Intergas Kombi Kompakt HRecoContrasted
Intergas HReco 36Intergas Kombi Kompakt HRecoContrasted
Intergas HR 22Intergas Kombi Kompakt HRContrasted
Intergas HR 28Intergas Kombi Kompakt HRContrasted
Intergas HR 28/24Intergas Kombi Kompakt HRContrasted
Intergas HR 36/30Intergas Kombi Kompakt HRContrasted
Intergas HRE 12Intergas Kompakt Solo HREContrasted
Intergas HRE 18Intergas Kompakt Solo HREContrasted
Intergas HRE 24Intergas Kompakt Solo HREContrasted
Intergas HRE 30Intergas Kompakt Solo HREContrasted
Intergas CW5Intergas PrestigeContrasted
Intergas CW6Intergas PrestigeContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 074507 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 074507. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor 074507 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The extractor does not start at all, with no noise or visible rotation.

    Cause: The motor may be blocked due to rust on the shaft or the winding burned out after years of use.

    Check with a multimeter that power is reaching the fan before replacing it; if there is no power, the issue may be with the PCB or the pressure switch itself.

  • 02

    The ignition is intermittent: sometimes the boiler starts up properly and other times it gets stuck halfway.

    Cause: An extractor that no longer spins at the same speed causes the pressure switch to close the contact irregularly.

    Repeat the startup several times in a row and note if the fault depends on whether the boiler is cold or hot; this information helps to narrow down the source.

  • 03

    A metallic rubbing or squeaking sound is heard when the fan is turned.

    Cause: The worn bearing allows the rotor blades to lightly rub against the casing.

    Check if the rubbing is constant or only at startup; if it is constant, it is advisable to rule out that something has come loose inside the casing.

  • 04

    The boiler is locking out with a warning related to the fan or flue gas evacuation.

    Cause: The pressure switch is not receiving the pressure signal that confirms the fan is properly expelling the flue gases.

    Check that the flue gas outlet to the outside is not obstructed by leaves, nests, or dirt before replacing the fan.

  • 05

    A burnt or hot plastic smell appears after a failed ignition attempt.

    Cause: A forced motor that does not turn smoothly can overheat and emit that smell.

    Disconnect the boiler and let it cool down; visually inspect the extractor for any burn marks before deciding on the replacement.

Fault codes Intergas that this part resolves

CodeFaultDiagnosis and solution
8Incorrect fan speedThe Torin-Sifan DSB144-22 fan/flue gas extractor (ref. 074507) does not rotate at the commanded speed or the rpm feedback is inconsistent; check that the impeller does not rub against the casing and the wiring between the fan and the burner control unit, and if the issue persists, replace the fan.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Extractor data sheet Intergas 074507

Catalogue reference
074507
Brand
Intergas
Type of part
Extractor fans
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently Asked Questions

Frequently asked questions about the extractor 074507

Does this flue extractor work for my Intergas Kombi Kompakt HRE 24/18?
Yes, the HRE 24/18 is on the list of boilers compatible with this extractor Ref. 074507.
When should the extractor of an Intergas Prestige CW5 be replaced?
It is replaced when the fan fails, makes excessive noise, or the boiler does not start due to a fault in the extractor.