Filling Key Baxi Roca Vega 24 Aifm Ref. 122621006
The Baxi Roca boilers from the Vega range use the Baxi Roca Vega 24 Aifm Filling Key, with reference 122621006. This key allows you to refill water into the heating circuit, which is essential for maintaining the proper pressure. If it fails, you will notice that you cannot refill the circuit or that it is continuously leaking water, which can lead to an increase in pressure. It is compatible with models such as Vega 20 AIM, Vega 24 AIM, Vega 20 AIFM, and Vega 24 AIFM, among others. It should be replaced when it shows leaks or does not function properly when trying to fill the circuit.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 122621006
Filling key with reference 122621006. Four confirmed compatibilities: Vega 20 AIM and Vega 24 AIM.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca Vega 20 AIM | Baxi Roca | Contrasted |
| Baxi Roca Vega 24 AIM | Baxi Roca | Contrasted |
| Baxi Roca Vega 20 AIFM | Baxi Roca | Contrasted |
| Baxi Roca Vega 24 AIFM | Baxi Roca | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 122621006 is the part for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122621006. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve 122621006 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler warns of low pressure or locks out, and when refilling, the pressure rises well but drops again in a few days.
Cause: The filling valve is not completely sealed and is slowly and constantly leaking water.
Close the valve, check the pressure, and see if it drops even if there are no radiators or bleed valves open in the house.
- 02
There is a ring of lime or dry drops around the faucet, although it is not dripping right now.
Cause: There has been an intermittent leak from the gasket or the cartridge that is more noticeable when heating the system.
Place kitchen paper under the tap for a whole day with the boiler operating normally and check if any moisture appears.
- 03
The key turns with difficulty or seems not to close completely until the end.
Cause: The internal mechanism gets stuck due to accumulated scale after a long period of disuse.
Before changing it, open and close it several times slowly to see if it releases the hard spot.
- 04
After filling, the needle of the pressure gauge continues to move on its own instead of staying fixed.
Cause: The valve allows a fine stream of water to pass even when it is in the closed position.
Mark the pressure with a marker on the glass of the manometer after closing it and check if it moves without having used heating.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Baxi Roca 122621006
- Catalogue reference
- 122621006
- Brand
- Baxi Roca
- Type of part
- Filling valves
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca Vega 24 AIFM Manual (PDF)Document © Baxi Roca, provided as a technical reference.