Filling Key Baxi Sara 24 24 F Ref. 122152510
The filling key Baxi Sara 24 24 F allows water to be replenished in the heating circuit to recover the necessary pressure. When it fails, the circuit cannot be refilled or may lose water, leading to an increase in pressure. This part is compatible with several Baxi models, including the Sara 24/24 S/P and the Sara 24/24 T, among others. A technician must confirm through diagnosis whether it needs to be replaced when you observe pressure issues or water leaks.
- Type of part
- Filling valves
- Status
- Refurbished
- Catalogue reference
- 122152510
- Warranty
- 1 year
Baxi Roca boilers compatible with reference 122152510
Filling key with reference 122152510. Six confirmed compatibilities: Sara 24/24 F and Sara 24/24 S/P.
Verified compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Roca Sara 24/24 F | Baxi Roca Sara | Verified |
| Baxi Roca Sara 24/24 S/P | Baxi Roca Sara | Verified |
| Baxi Roca Sara 24/24 T | Baxi Roca Sara | Verified |
| Roca Nora 24/24 F | Baxi Roca Nora | Verified |
| Baxi Roca Nora 24/24 S/P | Baxi Roca Nora | Verified |
| Baxi Roca Nora 24/24 T | Baxi Roca Nora | Verified |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 122152510 is the part for your boiler.
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122152510. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the filling valve 122152510
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
Do you see moisture or droplets on the faucet without having touched it?
Cause: The internal seal is not sealing properly and allows water to pass through continuously.
Dry the valve with the boiler cold and check if the moisture reappears before replacing it.
- 02
When opening to fill, the water comes in very slowly or hardly at all.
Cause: There may be limescale blocking the internal passage, or the mains valve is not fully open.
First, check the flow at the main shut-off valve before considering that this filling valve is faulty.
- 03
The connection with the network pipe leaks water when tightened.
Cause: The sealing of that thread is damaged, which is different from a fault in the body of the valve.
Check the condition of the gasket on that connection and tighten it again before replacing the entire valve.
- 04
The lever remains ajar and does not close completely.
Cause: Wear or dirt in the mechanism prevents the lever from closing completely.
Check that the lever makes a firm stop when closing, without getting stuck halfway, before changing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Baxi Roca 122152510
- Catalogue reference
- 122152510
- Uniclima internal SKU
- LLCRS2424F
- Brand
- Roca
- Type of part
- Filling valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days