Filling Key Manaut Minox Condens 24 E Ref. BI1181503
If you cannot refill water to the heating circuit or if you notice that water is continuously leaking, it is possible that the filling valve is damaged. The Filling Valve Biasi Minox Condens 24 E, with reference BI1181503, allows you to refill water to the circuit to recover the necessary pressure in the boiler. This part is compatible with models such as Minox Eco 24E and Minox Eco 28E, among others. It is recommended to replace it when it shows faults that prevent proper filling or cause leaks.
VAT included
Consult via WhatsAppBoilers Biasi compatible with reference BI1181503
Filling key with reference BI1181503. Two confirmed compatibilities: Minox Eco 24E and Minox Eco 28E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Minox Eco 24E | Minox Eco | Contrasted |
| Biasi Minox Eco 28E | Minox Eco | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number BI1181503 is the piece for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1181503. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve BI1181503 resolves.
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The faucet drips even when it's closed, and there is a puddle under the boiler.
Cause: The brass fitting or the rubber sleeve do not seal properly and allow water to pass through even when the valve is closed.
Check if the dripping comes from the rubber sleeve or from the fitting thread before considering the part damaged; sometimes it is only necessary to tighten the joint.
- 02
I can't increase the pressure in the circuit even when I open the valve.
Cause: The internal passage of the valve is blocked by scale or dirt and does not allow the flow of mains water.
Open the valve and check if water flows normally from the other end before replacing it.
- 03
It is difficult to turn the key; it is stiff or jammed.
Cause: The internal mechanism has become stuck due to lack of use or due to the accumulation of limescale on the stem.
Try to move it carefully in both directions; if it doesn't move, do not force it to avoid breaking the brass fitting.
- 04
After filling, the pressure continues to rise on its own over time.
Cause: The valve does not close completely and allows a continuous flow of mains water into the circuit.
Close it completely and observe the manometer for a couple of hours; if the pressure continues to rise, confirm that the problem is the valve and not another element of the filling circuit.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling valve Biasi BI1181503