Filling Key Heating Circuit Baxi Roca Laura 20 20F Ref. 122085010
The Filling Valve for the Heating Circuit Baxi Roca Laura 20 20F Ref. 122085010 is a component that allows water to be replenished in the heating circuit to maintain the proper pressure. When it fails, the user will notice that the circuit cannot be filled or that it is continuously leaking water, which can lead to an increase in pressure. This valve is compatible with several boilers, including models from the RS 20/20, R 20/20, and Laura ranges, among others. It is recommended to replace it when there are leaks or difficulties in filling the circuit.
VAT included
Consult via WhatsAppBaxi Roca boilers compatible with reference 122085010
Filling key with reference 122085010. 14 confirmed compatibilities: RS 20/20 and RS 20/20 F.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Baxi Roca RS 20/20 | RS 20/20 | Contrasted |
| Baxi Roca RS 20/20 F | RS 20/20 | Contrasted |
| Baxi Roca RS 20/20 T | RS 20/20 | Contrasted |
| Baxi Roca RSI 20/20 | RS 20/20 | Contrasted |
| Baxi Roca R 20/20 | R 20/20 | Contrasted |
| Baxi Roca R 20/20 F | R 20/20 | Contrasted |
| Baxi Roca R 30/30 | R 20/20 | Contrasted |
| Baxi Roca R 30/30 F | R 20/20 | Contrasted |
| Baxi Roca Laura 20/20 | Laura | Contrasted |
| Baxi Roca Laura 20/20 F | Laura | Contrasted |
| Baxi Roca Laura 30/30 | Laura | Contrasted |
| Baxi Roca Laura 35/35 | Laura | Contrasted |
| Baxi Roca Laura Plus 28/28 | Laura | Contrasted |
| Baxi Roca NR 15/20 | NR | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 122085010 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 122085010. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the filling valve 122085010 resolves
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler gradually loses pressure and the circuit needs to be refilled every few days.
Cause: The filling valve does not close completely and allows water to continuously flow into the heating circuit.
Close the valve completely and mark the pressure level; if it continues to rise with the valve closed, it is not sealing properly.
- 02
There is a drop of water or a ring of limescale on the floor, right below the boiler, at the level of the valve.
Cause: The gasket or the internal cartridge of the filling valve is damaged and leaking from the body.
Dry the area well, wait a while, and see if the drop reappears right at the valve before assuming that it is the source.
- 03
It is difficult to turn the key to fill it, or it is not clear when it is completely closed.
Cause: The brass cartridge gets stuck due to limescale or lack of use and loses its opening and closing stroke.
Turn carefully several times; if you notice a hard spot or it doesn't reach the stop, the cartridge is stuck.
- 04
After filling the circuit, the pressure does not remain stable and varies on its own.
Cause: The tap allows a trickle of water to pass through intermittently even though it seems to be closed.
Close the valve, note the exact pressure on the manometer, and compare it 24 hours later without touching anything else.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling key Baxi Roca 122085010
- Catalogue reference
- 122085010
- Brand
- Baxi Roca
- Type of part
- Filling valves
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Baxi Roca R 20/20 F manual (PDF)Document © Baxi Roca, provided as a technical reference.