Filling Key Junkers Eurosmart ZWA 24 1 AM Ref. 8716148072
The Junkers Eurosmart boilers use the Junkers Eurosmart ZWA 24 1 AM filling key, a tap that allows water to be replenished in the heating circuit, which is necessary to maintain the proper pressure. If this part fails, you may not be able to refill the circuit or it may leak water, which can lead to an increase in pressure. This model is compatible with several models in the Eurosmart range, such as the Eurosmart 24, the Eurosmart ZWA 24-1A23S2800, and others. A technician should confirm through diagnosis whether it needs to be replaced when filling issues or water leaks are detected.
- Type of part
- Filling valves
- Status
- Refurbished
- Catalogue reference
- 8716148072
- Warranty
- 1 year
Junkers boilers compatible with reference 8716148072
Filling key with reference 8716148072. Five confirmed compatibilities: Eurosmart 24 and Eurosmart ZWA 24-1A23S2800.
Verified compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Junkers Eurosmart 24 | Junkers | Verified |
| Junkers Eurosmart ZWA 24-1A23S2800 | Junkers | Verified |
| Junkers Eurosmart ZWA 24-1A31S2800 | Junkers | Verified |
| Junkers Eurosmart ZWA 24-1K23S2892 | Junkers | Verified |
| Junkers Eurosmart ZWA 24-1K31S2892 | Junkers | Verified |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 8716148072 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 8716148072. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the filling valve 8716148072
The filling valve allows water to refill the heating circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You need to recharge the pressure more frequently than usual.
Cause: The lever does not close properly and causes a constant internal leak.
Measure the pressure before and after a day without using the boiler to verify that the loss is continuous, not occasional.
- 02
Water comes out from the lever or from the base when it is closed.
Cause: The gasket of the mechanism has worn out with use.
Dry the area and observe for a few hours to ensure that the dripping is coming from the faucet and not from a nearby pipe.
- 03
The lever is stuck or difficult to move to recharge pressure.
Cause: The limescale deposits from the mains water block the internal mechanism over time.
Move the lever carefully in small increments; if it doesn't move, do not force it, as it could break before confirming that this is the fault.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the filling valve Junkers 8716148072
- Catalogue reference
- 8716148072
- Uniclima internal SKU
- LLEZWA241
- Brand
- Junkers
- Type of part
- Filling valves
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Junkers Eurosmart ZWA 24-1K23S2892 manual (PDF) Document © Junkers, provided as a technical reference.