Airsol Flow Meter Sensor HKB 224 Ref. 3003201466

Airsol Flow Meter Sensor HKB 224 Ref. 3003201466

Stock · 3 units

The Airsol Sensor HKB 224 flow meter detects the flow of water when a tap is opened and commands the ignition to produce domestic hot water. When it fails, you will notice that no hot water comes out even when the tap is open. This sensor is compatible with boilers from the Airsol HKB range, such as the HKB 224 and HKB 224 C models, as well as with other models from the brands Demrad, Heatline, and Glowworm. It should be replaced when there are issues with hot water production.

VAT included

Compatibility

Airsol boilers compatible with reference 3003201466

Flow meter with reference 3003201466. 11 confirmed compatibilities: HKB 224 and HKB 224 C.

Proven compatibility

Boiler modelFamilyVerification
Airsol HKB 224Airsol HKBContrasted
Airsol HKB 224 CAirsol HKBContrasted
Airsol AdenDemradContrasted
Airsol KalistoDemradContrasted
Airsol Kalisto MonoDemradContrasted
Airsol NitronDemradContrasted
Airsol NeptoDemradContrasted
Airsol CaprizHeatlineContrasted
Airsol SargonHeatlineContrasted
Airsol BetacomGlow-wormContrasted
Airsol EasicomGlow-wormContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 3003201466 is the part for your boiler.

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 3003201466. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter 3003201466 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When opening the hot water tap, the boiler does not ignite the burner.

    Cause: The flow detector does not inform the control board that there is flow, so the boiler does not heat.

    Open the tap fully and check if you notice weak pressure or flow in the mixture before changing the sensor.

  • 02

    The water comes out hot and cold intermittently while the tap is open.

    Cause: An irregular flow reading causes the boiler to modulate the burner in an unstable manner.

    Check that the water inlet filter is not partially blocked by scale or debris before replacing the sensor.

  • 03

    The boiler takes a long time to provide hot water or only works with the tap fully open.

    Cause: The flow detector requires a minimum flow rate to activate, and if it is dirty or damaged, it demands a higher flow rate than normal.

    Check the incoming water pressure and the condition of the filter before declaring the part defective.

  • 04

    The boiler provides hot water in some faucets of the house and not in others, inconsistently.

    Cause: This usually points to insufficient flow at that point in the installation rather than the sensor, although a turbine blocked by scale can exacerbate it.

    Test the faucet closest to the boiler with the maximum flow possible to rule out that the problem is with the installation before replacing the sensor.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the flow meter Airsol 3003201466

Catalogue reference
3003201466
Brand
Airsol
Type of part
Flow detectors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the flow meter 3003201466

Does this Airsol Sensor HKB 224 flow meter work for a Demrad Kalisto Mono?
Yes, the Demrad Kalisto Mono is on the list of boilers compatible with the Airsol Sensor HKB 224 flow meter, reference CSHKB224.
How can I verify that this flow meter is the correct one for my Glowworm boiler?
Compare the threaded black plastic body with that of your original sensor; this part has no visible text to help identify it, so physical comparison is the only available method.
Is this flow meter compatible with boilers from the Heatline range?
Yes, the Airsol Sensor HKB 224 flow meter is compatible with Heatline boilers, as well as with the Demrad and Glowworm ranges.
How many models are compatible with the Airsol Sensor HKB 224 flow meter?
This flow meter is compatible with a total of 11 models from different ranges.
What fault codes are documented for this flow meter?
There are no documented fault codes.

Spare parts related to Airsol Demrad

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Airsol Flow Meter Sensor HKB 224 Ref. 3003201466