Ariston Microgenus 27 MFFI Magnetic Flow Switch Ref. 65100519

Ariston Microgenus 27 MFFI Magnetic Flow Switch Ref. 65100519

Stock · 3 units

When you open the tap of your Ariston Microgenus 27 MFFI boiler, the magnetic flow switch detects the flow of water and activates the ignition to provide domestic hot water. If this part fails, you will notice that no hot water comes out even with the tap open. This flow switch is compatible with several models from the Microgenus range, as well as some from the Genus and EuroCombi ranges. It should be replaced when you experience issues with hot water supply or the fault code A10 appears.

VAT included

Compatibility

Ariston boilers compatible with reference 65100519

Flow meter with reference 65100519. Nine confirmed compatibilities: Microgenus 23 MFFI and Microgenus 27 MFFI.

Proven compatibility

Boiler modelFamilyVerification
Ariston Microgenus 23 MFFIMicrogenusContrasted
Ariston Microgenus 27 MFFIMicrogenusContrasted
Ariston Genus 23 MFFIGenusContrasted
Ariston Genus 27 MFFIGenusContrasted
Ariston Genus 27 BFFIGenusContrasted
Ariston Genus 27 RFFIGenusContrasted
Ariston Genus 30 MFFIGenusContrasted
Ariston EuroCombi A23 MFFIEuroCombiContrasted
Ariston EuroCombi A27 MFFIEuroCombiContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 65100519 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 65100519. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter 65100519 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    When opening the hot water tap, the boiler does not start the burner and the water comes out cold.

    Cause: The flow switch does not detect the flow of water and does not send the ignition signal for the domestic hot water.

    Open the tap to high flow for a few seconds and check if the LED indicator of the flow switch lights up before replacing it.

  • 02

    The water comes out hot in heating but never from the bathroom or kitchen faucet.

    Cause: The fault is in the domestic hot water circuit, as the flow switch is what activates that mode, while heating does not depend on it.

    Check the pressure and flow of the tap: with low mains pressure, the flow switch may not activate even if it is in good condition.

  • 03

    The LED indicator of the flow switch does not light up even though water is flowing through the pipe.

    Cause: The spring or the internal magnet of the flow switch does not move enough to close the magnetic contact.

    Check that the cold water inlet filter is not dirty or calcified, as this reduces the flow rate and may prevent the pressure switch from activating.

  • 04

    The hot water startup is irregular: sometimes it heats and sometimes it doesn't, depending on how hard the tap is opened.

    Cause: A pressure switch with a weakened spring requires more flow than usual to activate the contact.

    Open the tap to maximum flow and check if it starts like that; if it improves significantly, point to a sluggish flow switch before considering another cause.

Fault codes for Ariston that this part resolves.

CodeFaultDiagnosis and solution
A10Primary circuit flow switch (flow switch).Fault/blockage of the primary magnetic flow switch (ref. 65100519): the micro switch does not activate and the PCB does not detect flow in heating. Check the continuity of the micro switch and its operation when the pump starts; if it does not change state, clean or replace the assembly.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Ariston flow meter data sheet 65100519

Catalogue reference
65100519
Brand
Ariston
Type of part
Flow detectors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently Asked Questions

Frequently asked questions about the flow meter 65100519

Does this pressure switch Ref. 65100519 also work for an Ariston Genus 23 MFFI?
Yes, the Genus 23 MFFI is on the list of compatible boilers, along with the Genus 27 MFFI, the Eurocombi A23/A27 MFFI, and the Microgenus 23 MFFI.
What fault indicates that the pressure switch needs to be replaced in a Microgenus 27 MFFI?
The water flow is not detected and no hot water comes out when the tap is opened, because the boiler does not start the burner.
Does this pressure switch have a light indicator or just the mounting clip?
It includes both a red LED indicator and a mounting clip, as well as a visible metal retaining spring in the photo.

Spare parts related to Ariston Genus

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Ariston Microgenus 27 MFFI Magnetic Flow Switch Ref. 65100519