Ferroli Bluehelix PRO 32C Flow Meter Ref. I39846130

Ferroli Bluehelix PRO 32C Flow Meter Ref. I39846130

Stock · 1 unit

The Ferroli Bluehelix PRO 32C flow meter, with reference I39846130, is a flow detector that is responsible for detecting the flow of water when a tap is opened, thus activating the ignition to produce domestic hot water (DHW). If this part fails, you will notice that hot water does not come out even when the tap is open. It is compatible with boilers from the Bluehelix PRO range, including models such as Bluehelix PRO 25C and Bluehelix PRO 32C, among others. It is recommended to replace the flow meter when you experience a lack of hot water when opening the tap.

VAT included

Compatibility

Ferroli boilers compatible with reference I39846130

Flow meter with reference I39846130. Seven confirmed compatibilities: Bluehelix PRO 25C and Bluehelix PRO 32C.

Proven compatibility

Boiler modelFamilyVerification
Ferroli Bluehelix PRO 25CBluehelix PROContrasted
Ferroli Bluehelix PRO 32CBluehelix PROContrasted
Ferroli Bluehelix Tech 25CBluehelix Tech CContrasted
Ferroli Bluehelix Tech 35CBluehelix Tech CContrasted
Ferroli Twist PRO 25CTwist PROContrasted
Ferroli Superlative Condens 25CCointra Superlative CondensContrasted
Ferroli Superlative Condens 32CCointra Superlative CondensContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. I39846130 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference I39846130. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter I39846130 resolves

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    You turn on the hot water tap and the boiler does not start the production of domestic hot water.

    Cause: The flow detector does not send the water flow signal and the PCB does not activate the domestic hot water mode.

    Measure the flow rate at the tap and make sure it is the normal one for the house before considering changing the part.

  • 02

    The hot water is fluctuating, coming out hot and cold alternately without changing the faucet.

    Cause: The signal from the detector fluctuates due to internal dirt, and the boiler modulates the flame according to that irregular signal.

    Test another faucet in the house to see if the pull happens the same way, so you can rule out that it's an issue with that specific outlet.

  • 03

    In heating mode, the boiler works without any issues, but it fails only when requesting hot water.

    Cause: The flow detector operates only in the domestic hot water circuit, which is why the fault does not affect the heating.

    Check that the fault occurs every time you open a tap and never when the heating is running alone.

  • 04

    The display shows a warning or code associated with the flow sensor.

    Cause: The control unit receives an unexpected reading from the sensor and alerts or locks the equipment.

    Note the code as it appears and compare it with the manual before assuming that this is the part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Flow meter data sheet Ferroli I39846130

Catalogue reference
I39846130
Brand
Ferroli
Type of part
Flow detectors
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently Asked Questions

Frequently asked questions about the flow meter I39846130

Is this flow meter Ferroli Bluehelix PRO 32C Ref. I39846130 compatible with the Bluehelix PRO 25C?
Yes, the flow meter is compatible with the Bluehelix PRO 25C.
Can I use the Ferroli FCPRO32C flow meter in a Bluehelix Tech 35C?
No, the flow meter is not compatible with the Bluehelix Tech 35C.
Is this component suitable for a Twist PRO 25C?
Yes, the Ferroli Bluehelix PRO 32C flow meter is compatible with the Twist PRO 25C.
How many models are compatible with the Ferroli Bluehelix PRO 32C flow meter?
The flow meter is compatible with a total of 7 models.
Do the golden pins of the connector have any code engraved?
No, in the photos only the golden pins of the upper connector are visible; neither the casing nor the body has any visible text.
Does this flow meter work for a Cointra Superlative Condens 32C?
Yes, the Ferroli Bluehelix PRO 32C flow meter is compatible with the Cointra Superlative Condens 32C.

Spare parts related to Ferroli Bluehelix PRO

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Ferroli Bluehelix PRO 32C Flow Meter Ref. I39846130