Flow Detector Baxi Roca Victoria 20/20 F Ref. 122080480

Flow Detector Baxi Roca Victoria 20/20 F Ref. 122080480

Stock · 2 units

The Roca Victoria 20/20 F Flow Detector Ref. 122080480 is a flow switch that detects the flow of water when a tap is opened and activates the ignition to produce domestic hot water. When it fails, no hot water comes out even when the tap is open, which can generate fault codes such as 50-60-70-90: Open overtemperature thermostat (with flame). This component is compatible with Baxi Roca Victoria 20/20, Victoria 20/20 F, Victoria 20/20 T, and R 20/20 CXF boilers, among others. It should be replaced when the mentioned symptoms occur and no hot water is obtained when the tap is opened.

VAT included

Compatibility

Baxi Roca boilers compatible with reference 122080480

Flow meter with reference 122080480. Four confirmed compatibilities: Victoria 20/20 and Victoria 20/20 F.

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca Victoria 20/20Baxi RocaContrasted
Baxi Roca Victoria 20/20 FBaxi RocaContrasted
Baxi Roca Victoria 20/20 TBaxi RocaContrasted
Baxi Roca R 20/20 CXFBaxi RocaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part number 122080480 is the piece for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 122080480. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the flow meter 122080480 resolves.

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    There is no hot water coming out of the tap even though gas and cold water are reaching the boiler properly.

    Cause: The flow detector does not inform the PCB that there is water circulation, and the burner does not ignite for domestic hot water.

    Open the hot water tap fully and check that the flow is strong and constant; with low mains pressure, the sensor may not activate even if it is in good condition.

  • 02

    The burner ignites with a delay or intermittently when requesting hot water.

    Cause: The sensor detects the flow of water irregularly due to dirt, scale, or wear of the sensor element.

    Check if the cold water inlet filter is dirty or calcified before considering the part defective.

  • 03

    The heating works normally, but the domestic hot water never responds.

    Cause: This sensor only operates in the domestic hot water circuit, so a fault in it should not affect the heating.

    Confirm that the fault is exclusive to domestic hot water; if the heating also fails, the problem lies in another part, not in the flow sensor.

Fault codes for Baxi Roca that this part resolves.

CodeFaultDiagnosis and solution
50-60-70-90Overtemperature thermostat open (with flame).The DHW flow detector (122080480) may get stuck or send a false demand signal; the boiler ignites without opening the tap and, as the primary does not circulate, it overheats until the clixon trips. Check if it starts on its own without demand and measure the signal from the flow meter (pulses/continuity) and the condition of the magnet/turbine.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the flow meter Baxi Roca 122080480

Catalogue reference
122080480
Brand
Baxi Roca
Type of part
Flow detectors
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Type of connection
2-way connector (white)
Sensor element
Thermistor type (according to the appearance of the tip in the photo)
Frequently Asked Questions

Frequently asked questions about the flow meter 122080480

Is this flow detector compatible with the Baxi Roca Victoria 20/20 boiler?
Yes, the Roca Victoria 20/20 F flow detector (Ref. 122080480) is compatible with the Roca Victoria 20/20 boiler.
Can I use this detector on the Baxi Roca Victoria 20/20 T?
Yes, the Roca Victoria 20/20 F flow detector is compatible with the Roca Victoria 20/20 T boiler.
Is this detector suitable for the Baxi Roca Victoria 20/20 F?
Yes, the flow detector Baxi Roca Victoria 20/20 F is compatible with the boiler Baxi Roca Victoria 20/20 F.
How many models are compatible with this flow detector?
This flow detector is compatible with a total of 4 models from the Baxi Roca range.
What fault codes are documented for this product?
The documented fault codes for the Roca Victoria 20/20 F flow detector are: 50, 60, 70, and 90.
What is the reference for this flow detector?
The reference for the flow detector is CFRV2020F.

Spare parts related to Baxi Roca

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Flow Detector Baxi Roca Victoria 20/20 F Ref. 122080480