Flow switch Chaffoteaux Niagara Delta 30 FF Ref. 61304982
When you open a tap in your home, the Chaffoteaux Niagara Delta 30 FF flow switch Ref. 61304982 detects the flow of water and activates the ignition to heat the domestic hot water. If this component fails, you will notice that no hot water comes out even when the tap is open. This flow switch is compatible with Chaffoteaux Niagara Delta boilers, including models such as the Niagara Delta 24 FF and the Niagara Delta 30 FF, among others. It is advisable to replace it when you experience a lack of hot water when opening the taps.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61304982
Flow meter with reference 61304982. Three confirmed compatibilities: Niagara Delta 24 FF and Niagara Delta 30 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux Niagara Delta 24 FF | Chaffoteaux Niagara Delta | Contrasted |
| Chaffoteaux Niagara Delta 30 FF | Chaffoteaux Niagara Delta | Contrasted |
| Chaffoteaux Niagara Delta | Chaffoteaux Niagara Delta | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 61304982 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61304982. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter 61304982 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite the burner either in heating or in domestic hot water.
Cause: The flow switch does not detect circulation in the primary circuit and blocks ignition for safety.
Check that the pump is circulating and that there is no air in the circuit before replacing the pressure switch.
- 02
The boiler is locking out with a warning related to the flow or circulation of water.
Cause: The control unit interprets the lack of signal from the flow switch as an absence of circulation in the primary circuit.
Bleed the circuit and check that the pump rotates freely, without being stuck, before replacing the part.
- 03
It turns on occasionally but cuts off after a few seconds.
Cause: A dirty contact or wheel inside the flow switch sends an intermittent signal that the control board does not validate.
Measure the pressure of the installation with the manometer; it should be between 1 and 1.5 bar before discarding the part.
- 04
There is no visible fault in the pump, but the boiler still does not start the burner.
Cause: The fault may be in the flow sensor itself and not in the element that moves the water.
Isolate the component and check its electrical continuity with the circuit off before purchasing it.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Flow meter data sheet Chaffoteaux 61304982
- Catalogue reference
- 61304982
- Brand
- Chaffoteaux
- Type of part
- Flow detectors