Flow switch Chaffoteaux Niagara Delta 30 FF Ref. 61304982

Flow switch Chaffoteaux Niagara Delta 30 FF Ref. 61304982

When you open a tap in your home, the Chaffoteaux Niagara Delta 30 FF flow switch Ref. 61304982 detects the flow of water and activates the ignition to heat the domestic hot water. If this component fails, you will notice that no hot water comes out even when the tap is open. This flow switch is compatible with Chaffoteaux Niagara Delta boilers, including models such as the Niagara Delta 24 FF and the Niagara Delta 30 FF, among others. A technician should confirm through diagnosis whether it needs to be replaced when you experience a lack of hot water when opening the taps.

Type of part
Flow detectors
Catalogue reference
61304982
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Chaffoteaux boilers compatible with reference 61304982

Flow meter with reference 61304982. Three confirmed compatibilities: Niagara Delta 24 FF and Niagara Delta 30 FF.

Verified compatibility

Boiler modelFamilyVerification
Chaffoteaux Niagara Delta 24 FFChaffoteaux Niagara DeltaVerified
Chaffoteaux Niagara Delta 30 FFChaffoteaux Niagara DeltaVerified
Chaffoteaux Niagara DeltaChaffoteaux Niagara DeltaVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 61304982 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 61304982. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the flow meter 61304982

The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite the burner either in heating or in domestic hot water.

    Cause: The flow switch does not detect circulation in the primary circuit and blocks ignition for safety.

    Check that the pump is circulating and that there is no air in the circuit before replacing the pressure switch.

  • 02

    The boiler is locking out with a warning related to the flow or circulation of water.

    Cause: The control unit interprets the lack of signal from the flow switch as an absence of circulation in the primary circuit.

    Bleed the circuit and check that the pump rotates freely, without being stuck, before replacing the part.

  • 03

    It turns on occasionally but cuts off after a few seconds.

    Cause: A dirty contact or wheel inside the flow switch sends an intermittent signal that the control board does not validate.

    Measure the pressure of the installation with the manometer; it should be between 1 and 1.5 bar before discarding the part.

  • 04

    There is no visible fault in the pump, but the boiler still does not start the burner.

    Cause: The fault may be in the flow sensor itself and not in the element that moves the water.

    Isolate the component and check its electrical continuity with the circuit off before purchasing it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Flow meter data sheet Chaffoteaux 61304982

Catalogue reference
61304982
Uniclima internal SKU
FCND30FF
Brand
Chaffoteaux
Type of part
Flow detectors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

code engraved on the body
1304982
Frequently asked questions

Frequently asked questions about the flow meter 61304982

Does the sales code 61304982 match the code engraved on the Chaffoteaux Niagara Delta 30 FF pressure switch?
Yes, the code 61304982 is the one that is engraved on the body of the part.
How can I tell if the pressure switch of my Chaffoteaux Niagara Delta 30 FF boiler is faulty?
If the boiler does not ignite or gets blocked with water circulating through the primary circuit, it is likely that the pressure switch is faulty.
Is this pressure switch compatible with other models in the Chaffoteaux range?
Yes, it is compatible with the Niagara Delta 24 FF and Niagara Delta models.
What is the reference for the Chaffoteaux Niagara Delta 30 FF flow switch?
FCND30FF is Uniclima’s internal SKU for locating this listing. To confirm compatibility, check the manufacturer’s reference and the exact appliance model.
How many models are compatible with the Chaffoteaux Niagara Delta 30 FF flow switch?
There are a total of 3 compatible models.
Are there documented fault codes for this pressure switch?
No, there are no documented fault codes for this product.
Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model