Flow switch Cointra Ferroli Exclusive MIX 26 Ref. 39820450
The flow switch detects the flow of water when a tap is opened and commands the ignition to produce domestic hot water. If it fails, you will notice that no hot water comes out even though the tap is open. This component is compatible with several boilers, including models from the Divatop Low NOx, Divatop, Divatop Micro, Ferdigit, Eneconcept Tech, and Optimax HE ranges. A technician must confirm through diagnosis whether it needs to be replaced when there are issues with hot water supply. The manufacturer reference is 39820450.
- Type of part
- Flow detectors
- Status
- Refurbished
- Catalogue reference
- 39820450
- Warranty
- 1 year
Ferroli boilers compatible with reference 39820450
Flow meter with reference 39820450. 15 verified compatibilities: Divatop Low NOx F24 and Divatop Low NOx F32.
Verified compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Divatop Low NOx F24 | Divatop Low NOx | Verified |
| Ferroli Divatop Low NOx F32 | Divatop Low NOx | Verified |
| Ferroli Divatop F24 | Divatop | Verified |
| Ferroli Divatop C24 | Divatop | Verified |
| Ferroli Divatop C32 | Divatop | Verified |
| Ferroli Divatop F32 | Divatop | Verified |
| Ferroli Divatop F37 | Divatop | Verified |
| Ferroli Divatop Micro F24 | Divatop Micro | Verified |
| Ferroli Divatop Micro F32 | Divatop Micro | Verified |
| Ferroli Ferdigit F24 | Ferdigit | Verified |
| Ferroli Ferdigit Micro F24 | Ferdigit | Verified |
| Ferroli Econcept Tech 25C | Econcept Tech | Verified |
| Ferroli Econcept Tech 35C | Econcept Tech | Verified |
| Ferroli Optimax HE 31C | Optimax HE | Verified |
| Ferroli Optimax HE 38C | Optimax HE | Verified |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 39820450 is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 39820450. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis in the flow meter 39820450
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You turn on the hot water tap and the boiler does not ignite the burner to heat it.
Cause: The flow switch does not detect the rotation of the paddle wheel and does not send the start signal in DHW mode to the control board.
Check the mains pressure and make sure that the cold water inlet filter is not clogged with limescale before considering the part faulty.
- 02
The water comes out hot for a moment and then cools down, as if the burner turns off by itself.
Cause: The paddle wheel rotates with friction due to lime or dirt and sends an intermittent signal to the circuit.
Remove the flow switch and manually check that the wheel turns smoothly and without rubbing before replacing it.
- 03
The domestic hot water is not heating even though the boiler is working well for heating.
Cause: It is an isolated fault in the domestic hot water circuit because this flow switch only monitors that flow, not the heating one.
Check that the problem does not come from the mixer or the plate heat exchanger before replacing the flow switch.
- 04
When opening several taps at the same time, does the hot water take longer or not arrive?
Cause: With low flow, the wheel may not reach the minimum rotation required by the sensor to activate the burner.
Try opening a single tap at high flow and check if that makes it ignite.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Ferroli 39820450 flow meter datasheet
- Catalogue reference
- 39820450
- Uniclima internal SKU
- FCMIX26
- Brand
- Ferroli
- Type of part
- Flow detectors
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days