Flow meter Hermann Micraplus NOx 24 B 2 Ref. 0020097207
The Hermann Micraplus NOX 24 B 2 flow meter Ref. 0020097207 detects the flow of water when a tap is opened and commands the ignition to produce domestic hot water. If it fails, you will notice that hot water does not come out even when the tap is open. This component is compatible with boilers from the Hermann range, such as Micraplus 24 and Micraplus NOX 24, as well as models from Glowworm, Protherm, and Saunier Duval. It is recommended to replace it when it shows faults in the supply of hot water.
VAT included
Consult via WhatsAppHermann boilers compatible with reference 0020097207
Flow meter with reference 0020097207. 16 verified compatibilities: Ultracom 2 24CXI and Ultracom 2 30CXI.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Hermann Ultracom 2 24CXI | Glow-worm | Contrasted |
| Hermann Ultracom 2 30CXI | Glow-worm | Contrasted |
| Hermann Ultracom 2 35CXI | Glow-worm | Contrasted |
| Hermann Micraplus 24 | Hermann | Contrasted |
| Hermann Micraplus 30 | Hermann | Contrasted |
| Hermann Micraplus Condens 25 | Hermann | Contrasted |
| Hermann Micraplus NOx 24 | Hermann | Contrasted |
| Hermann Gepard (v19) | Protherm | Contrasted |
| Hermann Panther (v19) | Protherm | Contrasted |
| Hermann Duval Habitat 3 23 | Saunier | Contrasted |
| Hermann Duval Micra 3 24 | Saunier | Contrasted |
| Hermann Duval Micra 3 29 | Saunier | Contrasted |
| Hermann Duval Thema 3 25 | Saunier | Contrasted |
| Hermann Duval Thema 3 30 | Saunier | Contrasted |
| Hermann Duval Thesi 3 25 | Saunier | Contrasted |
| Hermann Duval Thesi 3 30 | Saunier | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the reference 0020097207 is the part for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 0020097207. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter 0020097207 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The domestic hot water is not heating even though the tap is open and the boiler has gas and electricity.
Cause: If the flow meter does not send the water flow signal, the boiler does not receive the command to start the burner for domestic hot water.
Make sure that the cold water inlet shut-off valve to the boiler is fully open before suspecting the sensor.
- 02
The burner takes several seconds to ignite after opening the tap, longer than usual.
Cause: A flow meter with the turbine partially seized by scale takes longer to reach the minimum rotation that activates the demand.
Open and close the tap several times in a row; if the delay increases each time, there may be dirt or limescale on the sensor.
- 03
The temperature of the hot water fluctuates on its own while the tap remains in the same position.
Cause: Irregular readings from the flow meter cause the PCB to modulate the burner erratically, even though the actual flow is constant.
First, rule out a faulty single control or thermostatic mixing valve, which causes the same symptom without the sensor failing.
- 04
The boiler indicates a low flow fault only when the water pressure in the house is low, but it works well the rest of the time.
Cause: The flow meter requires a minimum flow rate to activate; with low inlet pressure, that minimum is not always reached.
Measure the network pressure and flow rate at the boiler's inlet; if they are at the limit, try during a time period of higher pressure before changing the sensor.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Hermann flow meter data sheet 0020097207
- Catalogue reference
- 0020097207
- Brand
- Hermann
- Type of part
- Flow detectors
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days