Magnetic Flow Switch Manaut Micon 24 E Ref. BI1091104
The Magnetic Flow Switch Biasi Micon 24 E Ref. BI1091104 is a flow detector that is responsible for detecting the flow of water when a tap is opened, thus activating the ignition to produce domestic hot water. If this part fails, you will notice that hot water does not come out even with the tap open. It is compatible with boilers from the Minox range, such as the Minox 24 E model, among others. It is recommended to replace the flow switch when you experience a lack of hot water when opening the tap.
VAT included
Consult via WhatsAppBoilers Biasi compatible with reference BI1091104
Flow meter with reference BI1091104. A proven compatibility: Minox 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Minox 24 E | Minox | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number BI1091104 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI1091104. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the flow meter BI1091104 resolves.
The flow meter detects the passage of water to activate the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
You turn on the hot water tap and the boiler does not ignite, although the pilot light is working and there is gas.
Cause: The flow detector does not detect the flow of water and does not send the command to turn on the burner.
Check that the cold water inlet filter is not blocked by scale or dirt and that the tap is fully open.
- 02
The hot water comes out in bursts, it turns on and off several times while the tap is still running.
Cause: The internal palette of the detector moves irregularly due to accumulated scale or because the flow is just at the minimum limit.
Check the network pressure and make sure there is no other tap open that reduces the flow to the boiler.
- 03
The heating works without any issues, but the domestic hot water never starts up.
Cause: This detector only operates in the domestic hot water circuit: if the contact does not close, the control unit does not receive the demand signal.
Check that the fitting and the filter before the part are free of scale before declaring it faulty.
- 04
You notice humidity or a small drip in the area where the detector is mounted.
Cause: The body gaskets wear out over time and lose their sealing ability.
Dry the area, tighten the fittings, and locate the exact point of the leak before replacing the entire part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Flow meter Biasi BI1091104
- Catalogue reference
- BI1091104
- Brand
- Manaut
- Type of part
- Flow detectors
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Indicator light
- red LED