Manaut Gas Valve GLM 4 16
The Manaut GLM 4 16 boilers use the Manaut GLM 4 16 gas valve, which is responsible for regulating and allowing the flow of gas to the burner according to the commands from the control board. When this valve fails, it is possible that the boiler does not ignite, that flame lockouts occur, or that gas modulation does not function properly. This model is compatible with the GLM 4 16 range from Manaut, among others. It is recommended to replace the valve when these symptoms appear to restore the proper functioning of the boiler.
VAT included
Consult via WhatsAppCompatible Biasi boilers
Gas valve. A proven compatibility: GLM 4 16.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi GLM 4 16 | Manaut | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the gas valve resolves
The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and there is no flame displayed.
Cause: The valve does not allow gas to flow to the burner even though the PCB sends the opening command.
Check that the gas valve is open and that the inlet pressure is normal before considering the valve as faulty.
- 02
The flame rises and falls without you having touched the water tap.
Cause: The coils that regulate the opening fail intermittently and the gas flow varies uncontrollably.
Check if the fault occurs only when more than one hot water point is open at the same time, before attributing it to the gas valve.
- 03
Do you notice a slight smell of gas near the boiler even when it is turned off?
Cause: Over time, the internal seals of the gas valve lose tightness and allow gas to pass when at rest.
If you smell gas, turn off the main valve and ventilate the area before taking any action: do not use the boiler until it has been checked.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.