Gas Shut-off Valve Chaffoteaux ET Maury Celtic 2 24 RSC Ref. 60044500

Gas Shut-off Valve Chaffoteaux ET Maury Celtic 2 24 RSC Ref. 60044500

The gas valve regulates and allows the flow of gas to the burner under the control of the PCB. If it fails, the boiler does not ignite, may experience flame lockouts, or show failed ignition attempts. This shut-off valve is compatible with Chaffoteaux ET Maury boiler models, such as the Celtic 2.24 RSC and Celtic 2.20 FF, among others. A technician must confirm through diagnosis whether it needs to be replaced when symptoms of failure occur, such as the absence of flame or ignition problems.

Type of part
Gas valves
Catalogue reference
60044500
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Chaffoteaux boilers compatible with reference 60044500

Gas valve with reference 60044500. Six confirmed compatibilities: Celtic 2.24 RSC and Celtic 2.20 FF.

Verified compatibility

Boiler modelFamilyVerification
Chaffoteaux Celtic 2.24 RSCCelticVerified
Chaffoteaux Celtic 2.20 FFCelticVerified
Chaffoteaux Flexiflame 140FlexiflameVerified
Chaffoteaux Flexiflame 130FlexiflameVerified
Chaffoteaux Corvec 140CorvecVerified
Chaffoteaux Moduloflame 140ModuloflameVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 60044500 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 60044500. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the gas valve 60044500

The gas valve regulates and modulates the gas flow to the burner. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The lever does not cut off the gas when turned.

    Cause: The internal ball of the valve does not rotate completely or is misaligned with the gas passage.

    With the lever in the closed position, check with soapy water at the outlet if gas is still leaking.

  • 02

    There is a gas leak from the shut-off valve.

    Cause: The lever shaft seal is dry and allows gas to escape when turning or even at rest.

    Apply soapy water to the lever shaft and the inlet and outlet threads to locate the leak.

  • 03

    The lever is stiff or does not move.

    Cause: The ball or the internal shaft has seized up due to rust or accumulated dirt after years of disuse.

    Do not force the lever dry: if it does not move with moderate pressure, the valve needs to be replaced before breaking it.

Chaffoteaux fault codes that require diagnosis

CodeFaultTechnical checks
5 01Flame absence.If the gas shut-off valve (ref. 60044500) is closed, seized, or obstructed, gas will not reach the burner and the boiler will not detect a flame. Check that the handle is fully open (parallel to the pipe) and compare pressure before/after the valve to rule out throttling.
501Flame absence (lockout).With the shut-off valve 60044500 closed or failing internally, there is no gas supply and the ignition does not succeed, causing lockout 501. Check for full opening of the valve and gas continuity up to the burner manifold.
5 P1First ignition attempt failed.The shut-off valve 60044500 closed/partially closed prevents the gas flow on the first attempt, so the flame is not established. Check the valve position and the inlet pressure to the gas valve during the attempt.
5 P2Second ignition attempt failed.If the shut-off valve 60044500 remains closed or is restricting the flow, the second attempt also fails due to lack of gas. Confirm full opening and absence of significant pressure drop at the valve outlet with ignition demand.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the gas valve Chaffoteaux 60044500

Catalogue reference
60044500
Uniclima internal SKU
LLGC1823
Brand
Chaffoteaux
Type of part
Gas valves
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently asked questions

Frequently asked questions about the gas valve 60044500

Is this gas shut-off valve compatible with the Chaffoteaux Celtic 2.20 FF as well as the Celtic 2.24 RSc?
Yes, it is confirmed for Celtic 2.20 FF, Celtic 2.24 RSc, and Flexiflame 140.
Does this gas shut-off valve work for the Chaffoteaux Flexiflame 140?
Yes, it is among the three confirmed models: Celtic 2.20 FF, Celtic 2.24 RSc, and Flexiflame 140.