Ariston Clas Premium EVO 24 PCB Ref. 60001898 04
The Ariston Clas Premium EVO 24 04 PCB is the control device that manages the ignition, burner modulation, pump, and safety features of the boiler. If it malfunctions, the boiler may fail to start, lock out, or behave erratically. The fault codes that may appear are 3 03, 3 05, 3 06, and 3 07. This PCB is compatible with models from the Ariston Clas Premium Evo and Genus Premium Evo ranges, among others. It should be replaced when the mentioned symptoms are detected or in case of a fault.
VAT included
Consult via WhatsAppAriston boilers compatible with reference 60001898 04
PCB with reference 60001898 04. 11 verified compatibilities: Clas Premium Evo 24 and Clas Premium Evo 30.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ariston Clas Premium Evo 24 | Ariston Clas Premium Evo | Contrasted |
| Ariston Clas Premium Evo 30 | Ariston Clas Premium Evo | Contrasted |
| Ariston Clas Premium Evo 35 | Ariston Clas Premium Evo | Contrasted |
| Ariston Clas B Premium Evo 24 | Ariston Clas Premium Evo | Contrasted |
| Ariston Clas B Premium Evo 35 | Ariston Clas Premium Evo | Contrasted |
| Ariston Genus Premium Evo 24 | Ariston Genus Premium Evo | Contrasted |
| Ariston Genus Premium Evo 30 | Ariston Genus Premium Evo | Contrasted |
| Ariston Genus Premium Evo 35 | Ariston Genus Premium Evo | Contrasted |
| Ariston Genus Premium Evo System 24 | Ariston Genus Premium Evo | Contrasted |
| Ariston Genus Premium Evo System 30 | Ariston Genus Premium Evo | Contrasted |
| Ariston Genus Premium Evo System 35 | Ariston Genus Premium Evo | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 60001898 04 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 60001898 04. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB 60001898 04 resolves.
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler shows no signs of life: display off, no fan noise.
Cause: The PCB does not distribute the electrical power to the rest of the equipment.
Check the mains voltage and the fuse on the PCB before declaring it faulty.
- 02
The display shows a fixed fault code that does not disappear upon reset.
Cause: The electronics detect a safety fault and lock the operation.
Note the exact code and check the manual: it may indicate a sensor or the pressure switch, not the PCB.
- 03
You change the temperature on the control and the boiler does nothing.
Cause: The PCB does not receive or interpret the heat demand signal.
Try turning on the boiler in direct manual mode to rule out the control wiring.
- 04
It turns on for domestic hot water but not for heating, or vice versa.
Cause: The relay or the switching valve between circuits managed by the PCB is not switching correctly.
Check manually that the three-way valve moves freely before replacing the PCB.
- 05
The boiler turns off by itself in the middle of a cycle or restarts without warning.
Cause: An unstable reading in the electronics causes unrequested stops and starts.
Check that the connectors on the PCB are neither loose nor damp before replacing it.
Fault codes for Ariston that this part resolves.
| Code | Fault | Diagnosis and solution |
|---|---|---|
| 3 03 | Main PCB fault | Internal fault of the PCB (internal power supply or logic stages). Check 230 V to the board and 5/12 V regulated and fuse; if it persists with peripherals disconnected, confirm by replacing the board. |
| 3 05 | Main PCB fault | Hardware anomaly detected by the PCB's self-diagnosis. Check power supply, ground connections, and connectors; if voltages are correct and the error reappears after reset, confirm by replacing the PCB. |
| 3 06 | Main PCB fault | PCB error (fault in components or internal regulations). Measure auxiliary voltages and check connectors/corrosion; if stable and without external loads, replace the PCB. |
| 3 07 | Main PCB fault | Critical persistent fault of the PCB. Disconnect external loads (pump, fan, valve) to rule out shorts; if the error persists, the board is faulty and must be replaced. |
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Ariston PCB 60001898 04
- Catalogue reference
- 60001898 04
- Brand
- Ariston
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Transformer brand
- COMELIT
- Varistor component
- EPCOS
- Silkscreened connection terminals
- L, N, SOL, TNL, SS
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ariston Clas Premium Evo 24 Manual (PDF)Document © Ariston, provided as a technical reference.