Fontecal Miniplus 25 XER PCB Ref. R107062
The control PCB of the Fontecal Miniplus 25 XER manages the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or behave erratically. This part is compatible with several models from the Fontecal Minitech and Minitech-Plus ranges, such as the Minitech-Plus 25 SER and the Minitech 30 XER, among others. It should be replaced when these malfunction symptoms occur.
VAT included
Consult via WhatsAppFontecal boilers compatible with reference R107062
PCB with reference R107062. Eight confirmed compatibilities: Minitech 25 XER and Minitech 25 SER.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Fontecal Minitech 25 XER | Fontecal Minitech (V.02) | Contrasted |
| Fontecal Minitech 25 SER | Fontecal Minitech (V.02) | Contrasted |
| Fontecal Minitech 30 XER | Fontecal Minitech (V.02) | Contrasted |
| Fontecal Minitech 30 SER | Fontecal Minitech (V.02) | Contrasted |
| Fontecal Minitech-Plus 25 XER | Fontecal Minitech-Plus / Miniplus (V.02) | Contrasted |
| Fontecal Minitech-Plus 25 SER | Fontecal Minitech-Plus / Miniplus (V.02) | Contrasted |
| Fontecal Miniplus 25 XER | Fontecal Minitech-Plus / Miniplus (V.02) | Contrasted |
| Fontecal Miniplus 30 XER | Fontecal Minitech-Plus / Miniplus (V.02) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number R107062 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R107062. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the PCB R107062 resolves
The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler control does not respond to anything, it neither turns on nor changes the temperature.
Cause: The microcontroller on the PCB has stopped processing user commands.
Check that the wiring from the control panel to the PCB is properly connected before replacing the PCB.
- 02
The boiler tries to ignite and shuts off after a few seconds, repeating the attempt unsuccessfully.
Cause: The PCB controls the ignition and stops the process if it detects that something is not working as it should.
Check the water pressure and the gas supply before blaming the PCB: if both are correct, the problem may be there.
- 03
A fault code is displayed and the boiler cannot be reset from the panel.
Cause: The electronics are locked in safety mode and do not allow a reset even though there is no longer an original cause.
Turn off the main power for a couple of minutes and turn it back on: if the manual reset does not work, the fault is in the PCB.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Fontecal R107062 PCB.
- Catalogue reference
- R107062
- Brand
- Fontecal
- Type of part
- PCBs (control boards)
- Units in stock
- 1 unit
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Voltage
- 230V
- Frequency
- 50-60Hz
- Transformer assembly code
- 350.1A106