Main PCB Ariston Clas ONE 24 Ref. 65116585 06

Main PCB Ariston Clas ONE 24 Ref. 65116585 06

Stock · 2 units

The Main PCB Ariston Clas ONE 24, with reference 65116585, is the component that controls the ignition, burner modulation, pump, and safety features of the boiler. When it fails, the boiler may not start, become locked, or operate erratically. Users may notice this malfunction through fault codes such as 302, 303, 305, 306, or 307. This board is compatible with models from the Clas ONE range, such as the Clas ONE 24, Clas ONE WiFi 24, Clas ONE WiFi 30, and Clas ONE WiFi 35, among others. It is recommended to replace it when the mentioned symptoms occur.

VAT included

Compatibility

Ariston boilers compatible with reference 65116585 06

PCB with reference 65116585 06. Six confirmed compatibilities: Clas ONE 24 and Clas ONE WiFi 24.

Proven compatibility

Boiler modelFamilyVerification
Ariston Clas ONE 24Clas ONEContrasted
Ariston Clas ONE WiFi 24Clas ONEContrasted
Ariston Clas ONE WiFi 30Clas ONEContrasted
Ariston Clas ONE WiFi 35Clas ONEContrasted
Ariston Clas B ONE 35Clas B ONEContrasted
Ariston Clas B ONE WiFi 35Clas B ONEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 65116585 06 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 65116585 06. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the PCB 65116585 06 resolves.

The PCB controls the ignition, modulation, and safety features of the boiler. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler is completely off, with no lights or display when connected to the power supply.

    Cause: The PCB controls the power supply to the entire boiler; if it is damaged, no current reaches any component.

    Check the fuse and the power supply of the boiler before considering replacing the PCB.

  • 02

    An error code appears on the screen that does not disappear even after resetting.

    Cause: The electronics block the boiler when detecting a problem and cannot resolve it on its own.

    Note the code and cut the power for one minute; if the fault reappears, the PCB is the one that is failing.

  • 03

    In the WiFi versions, the boiler does not connect to the app nor can it be paired with the mobile.

    Cause: The WiFi module is located on the PCB and can fail even if the boiler is functioning properly.

    Bring the router closer and reset the boiler before thinking that the WiFi module is broken.

  • 04

    The remote control or thermostat does not turn on the boiler even though it shows a temperature.

    Cause: The PCB does not receive or process the power-on command from the remote control or the communication system.

    Check the wiring of the control in the terminals of the PCB before replacing it.

Fault codes for Ariston that this part resolves.

CodeFaultDiagnosis and solution
302Internal communication faultThe main PCB may stop communicating with the display or the modules due to an issue with the board itself, such as a failure in the transceiver or problems with the soldering. Check the voltages on the board, the cables, and the connectors. Test with another display to rule out that it is the problem. If it continues to fail, the board needs to be replaced.
303Fault in the main PCB.The self-diagnostic system has detected a fault in the PCB that prevents it from functioning properly. Check the power supplies and the ground connections of the PCB. If you don't find any external issues, the PCB will need to be replaced.
305Fault in the main PCB.An internal fault in the PCB causes it to lock for safety reasons. Check that 230 V and 5 V are reaching it, review the ground connections and the connectors. If everything is fine and the fault reappears, the PCB needs to be replaced.
306Fault in the main PCB.There is a recurring fault in the PCB, whether in the circuits, the relays, or the regulation. Check the power supplies and the communications on the board. If you do not find external issues and the fault persists after a reset, the board needs to be replaced.
307Fault in the main PCB.The self-diagnosis has detected an internal problem in the PCB. Check the voltages, the bus, and the inputs. If the sensors and the wiring are fine, the solution is to replace the PCB.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Ariston PCB 65116585 06

Catalogue reference
65116585 06
Brand
Ariston
Type of part
PCBs (control boards)
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently Asked Questions

Frequently asked questions about the PCB 65116585 06

Does this PCB fit an Ariston CLAS ONE WIFI 30 boiler?
Yes, it is on the list of compatible models, which includes several versions of CLAS ONE, CLAS B ONE, and THISION MINI.

Spare parts related to Ariston Clas ONE

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model