Airsol Heat Line HK B130 Plate Heat Exchanger
The Airsol Heat Line HK B130 plate heat exchanger transfers heat from the primary circuit to the domestic hot water instantly. When it fails, the water comes out lukewarm or with fluctuating temperature, and the flow of DHW decreases. This heat exchanger is compatible with models such as the HK B124 and HK B130, among others in the Heat Line / Airsol range. It is recommended to replace it when these symptoms occur to ensure an adequate supply of hot water.
VAT included
Consult via WhatsAppAirsol boilers compatible with reference D001060233, 3003200026
Plate heat exchanger with reference D001060233, 3003200026. Two confirmed compatibilities: HK B124 and HK B130.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Airsol HK B124 | Heat Line / Airsol | Contrasted |
| Airsol HK B130 | Heat Line / Airsol | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number D001060233, 3003200026 is the correct one for your boiler?
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference D001060233, 3003200026. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the plate heat exchanger D001060233, 3003200026 solves.
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The domestic hot water comes out at a lower temperature than what is indicated on the panel, especially with the tap quite open.
Cause: The limescale buildup inside the heat exchanger reduces the heat transfer between the boiler circuit and the domestic hot water.
Before changing it, check if the flow of hot water has also decreased: if the temperature is normal with low flow, first check the inlet filter.
- 02
The boiler heats the radiators well, but the hot water from the tap doesn't get fully heated.
Cause: The heat exchanger distributes heat less effectively to the domestic hot water circuit when its channels are partially blocked.
Check the domestic hot water temperature set on the panel and if the burner reaches maximum power when requesting hot water.
- 03
You notice that you need to replenish pressure in the heating circuit more frequently than usual.
Cause: An internal leak in the heat exchanger plates can transfer water between circuits without any visible dripping outside.
First, rule out the expansion vessel and the automatic air vents, as they are the most common cause of this symptom.
- 04
The hot water is coming out with a lower flow rate than usual, although the pressure in the house is the same as always.
Cause: A heat exchanger with narrowed channels due to limescale allows less domestic hot water to pass through its interior.
Check the cold water inlet filter of the boiler before replacing the part: it often gets clogged before the heat exchanger itself.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the plate heat exchanger Airsol D001060233, 3003200026
- Catalogue reference
- D001060233, 3003200026
- Brand
- Airsol
- Type of part
- Plate heat exchanger
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days