Biasi / Biasi Mura Plate Heat Exchanger Ref. BI118112
Biasi and Manaut present the Mura Plate Heat Exchanger Ref. BI118112, a component that transfers heat from the primary circuit to the domestic hot water instantly. When this part fails, you will notice that the water comes out lukewarm or with fluctuating temperature, and the flow of domestic hot water decreases. This heat exchanger is compatible with models such as Mura 24 E, Mura V09 24 E, Midas 24 E, Midas Eco 24, Micon 23 E, among others. It is recommended to replace it when you experience these symptoms of inefficiency.
VAT included
Consult via WhatsAppBoilers Biasi compatible with reference BI118112
Plate heat exchanger with reference BI118112. Six confirmed compatibilities: Mura 24 E and Mura V09 24 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi Mura 24 E | Manaut | Contrasted |
| Biasi Mura V09 24 E | Manaut | Contrasted |
| Biasi Midas 24 E | Manaut | Contrasted |
| Biasi Midas Eco 24 | Manaut | Contrasted |
| Biasi Micon 23 E | Manaut | Contrasted |
| Biasi Mura 24 | Biasi | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part number BI118112 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference BI118112. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the heat exchanger BI118112 resolves.
The plate heat exchanger transfers heat to the domestic hot water. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
There is no hot water or it comes intermittently, sometimes hot and other times cold.
Cause: The plates are partially blocked by limescale, which causes irregular heat exchange.
Open and close the tap several times in a row: if the fault is more noticeable after a while without using hot water, check the scale before replacing the part.
- 02
The water comes out lukewarm, neither cold nor really hot.
Cause: The plates are partially covered, preventing the heat exchanger from transferring all the necessary heat.
Observe the flame in DHW mode: if it is stable and the water still does not heat, the problem is more likely related to the heat exchanger than to combustion.
- 03
The tap temperature suddenly changes when you open or close another water point in the house.
Cause: The flow passing through the plates varies, and a blocked heat exchanger does not respond as quickly.
Try using a single hot water tap and check if the temperature fluctuation remains the same: if it disappears, it could be a pressure issue and not related to the heat exchanger.
- 04
Water is appearing at the base of the boiler near the plate block.
Cause: The PCBs lose tightness with pressure and temperature cycles, and water escapes from there.
Dry the area and force a domestic hot water cycle; if the dripping reappears in that area, confirm the leak before requesting the spare part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Plate heat exchanger data sheet Biasi BI118112
- Catalogue reference
- BI118112
- Brand
- Manaut
- Type of part
- Plate heat exchanger
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days