Beretta Exclusive MIX26 Pressure Gauge Ref. R10027135
The Beretta Exclusive MIX26 manometer is a aquastat that measures and controls the pressure or temperature of your boiler's circuit. If it malfunctions, you may notice incorrect readings, which can cause the boiler to lock out due to a false lack of pressure or not regulate the temperature properly. This manometer is compatible with several models from the Exclusive range, such as the Exclusive Mix 26, Exclusive Green, and Exclusive Micromix 26, among others. It is recommended to replace it when the readings are not accurate or when the boiler is not functioning correctly.
VAT included
Consult via WhatsAppBeretta boilers compatible with reference R10027135
Pressure gauge with reference R10027135. Nine confirmed compatibilities: Exclusive Mix 26 and Exclusive (range).
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta Exclusive Mix 26 | Exclusive | Contrasted |
| Beretta Exclusive (range) | Exclusive | Contrasted |
| Beretta Exclusive Green | Exclusive | Contrasted |
| Beretta Exclusive Green E/HE | Exclusive | Contrasted |
| Beretta Exclusive Micromix 26 | Exclusive | Contrasted |
| Beretta Exclusive Sinthesi | Exclusive | Contrasted |
| Beretta Exclusive Boiler Green | Exclusive | Contrasted |
| Beretta Kompakt | Kompakt | Contrasted |
| Beretta Tower Green HE | Tower Green HE | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part R10027135 is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10027135. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge R10027135 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The manometer does not show pressure, neither when the boiler is cold nor when it is operating.
Cause: The internal mechanism that translates the water pressure is stuck.
Bleed a radiator to change the pressure and check if the needle moves, even if it's just a little.
- 02
The needle remains fixed at a point, regardless of whether the actual pressure changes.
Cause: There may be lime or corrosion in the mechanism, preventing the movement of the needle.
Compare the pressure you observe at the filling valve; if it varies there and not on the manometer, the part is failing.
- 03
Moisture or dripping is observed where the pressure gauge connects to the circuit.
Cause: The gasket or the connection fitting has lost its tightness over time.
Gently tighten the fitting and dry the area before deciding to replace the pressure gauge.
- 04
The black casing has cracks or does not fit properly to the control panel.
Cause: The plastic has deteriorated due to the heat from the boiler or has been damaged in a previous installation.
Make sure it’s not just a loose anchor before requesting the complete part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.