Beretta Thermohydrometer Pressure Temperature Arte 24 CAI Ref. R10026051
Thermomanometer for Beretta boilers from the Arte N, Piramide Condens, and Quadra ranges. It simultaneously measures the circuit pressure (scale 0-4 bar) and the flow temperature (scale 0-120°C) using two copper capillaries at the back. It should be replaced when the needle does not move, gets stuck, or the reading does not match the actual system pressure.
VAT included
Consult via WhatsAppBeretta boilers compatible with the reference R10026051
Manometer with reference R10026051. 11 verified compatibilities: N and Condens S 21.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Beretta N | Art | Contrasted |
| Beretta Condens S 21 | Pyramid | Contrasted |
| Beretta Condensing K 28 S 130 | Pyramid | Contrasted |
| Beretta 1 One 16 IE FF TS | Quadra | Contrasted |
| Beretta 1 One 20 IE FF TS | Quadra | Contrasted |
| Beretta 20 IE | Quadra | Contrasted |
| Beretta 20 IE FF TS | Quadra | Contrasted |
| Beretta 24 IE | Quadra | Contrasted |
| Beretta 24 IE FF | Quadra | Contrasted |
| Beretta 24 IE FF TS | Quadra | Contrasted |
| Beretta One 20 IE FF TS | Quadra | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part R10026051 is the one for your boiler.
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference R10026051. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the manometer R10026051 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure gauge does not move or is stuck at a value.
Cause: The pressure capillary has lost signal transmission due to breakage, bending, or internal leakage.
Check the pressure capillary path and ensure that it is not bent at a sharp angle, crushed by another component, or broken.
- 02
The temperature gauge is not showing anything, although the pressure gauge is functioning normally.
Cause: By having two independent capillaries, one for pressure and the other for temperature, each can fail separately without affecting the other.
Check that the temperature capillary, the one attached to the supply pipe, is still securely fixed and has not come loose from its housing.
- 03
The pressure indicated by the gauge does not match the actual pressure in the circuit.
Cause: A capillary with a slow leak or a misaligned mechanism may continue to move but provide a false reading.
Compare the reading with a portable manometer at a bleed valve, or check if the pressure rises in the expected proportion after refilling.
- 04
The dial is broken, scratched, or completely unreadable.
Cause: A blow or normal wear can damage the glass or the printed dial, even if the mechanism behind it continues to function.
If you can still sense the movement of the needles despite the visual damage, you can orient yourself approximately while the spare part arrives, but do not adjust the pressure or heating relying on that reading.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Beretta R10026051 pressure gauge.
- Catalogue reference
- R10026051
- Brand
- Beretta
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure range
- 0-4 bar
- Temperature range
- 0-120 °C
- The component code is also not available; it can only be verified by the internal reference R10026051.