Beretta Thermohydrometer Pressure Temperature Arte 24 CAI Ref. R10026051

Beretta Thermohydrometer Pressure Temperature Arte 24 CAI Ref. R10026051

Thermomanometer for Beretta boilers from the Arte N, Piramide Condens, and Quadra ranges. It simultaneously measures the circuit pressure (scale 0-4 bar) and the flow temperature (scale 0-120°C) using two copper capillaries at the back. Replacement requires first confirming the fault of the part through technical diagnosis, even when the needle does not register, is stuck, or the reading does not match the actual system pressure.

Catalogue reference
R10026051
Warranty
1 year
VAT included Stock · 4 units
Compatibility

Beretta boilers compatible with the reference R10026051

Manometer with reference R10026051. 11 verified compatibilities: N and Condens S 21.

Verified compatibility

Boiler modelFamilyVerification
Beretta NArtVerified
Beretta Condens S 21PyramidVerified
Beretta Condensing K 28 S 130PyramidVerified
Beretta 1 One 16 IE FF TSQuadraVerified
Beretta 1 One 20 IE FF TSQuadraVerified
Beretta 20 IEQuadraVerified
Beretta 20 IE FF TSQuadraVerified
Beretta 24 IEQuadraVerified
Beretta 24 IE FFQuadraVerified
Beretta 24 IE FF TSQuadraVerified
Beretta One 20 IE FF TSQuadraVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part R10026051 is the one for your boiler.

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10026051. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the manometer R10026051

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure gauge does not move or is stuck at a value.

    Cause: The pressure capillary has lost signal transmission due to breakage, bending, or internal leakage.

    Check the pressure capillary path and ensure that it is not bent at a sharp angle, crushed by another component, or broken.

  • 02

    The temperature gauge is not showing anything, although the pressure gauge is functioning normally.

    Cause: By having two independent capillaries, one for pressure and the other for temperature, each can fail separately without affecting the other.

    Check that the temperature capillary, the one attached to the supply pipe, is still securely fixed and has not come loose from its housing.

  • 03

    The pressure indicated by the gauge does not match the actual pressure in the circuit.

    Cause: A capillary with a slow leak or a misaligned mechanism may continue to move but provide a false reading.

    Compare the reading with a portable manometer at a bleed valve, or check if the pressure rises in the expected proportion after refilling.

  • 04

    The dial is broken, scratched, or completely unreadable.

    Cause: A blow or normal wear can damage the glass or the printed dial, even if the mechanism behind it continues to function.

    If you can still sense the movement of the needles despite the visual damage, you can orient yourself approximately while the spare part arrives, but do not adjust the pressure or heating relying on that reading.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Beretta R10026051 pressure gauge.

Catalogue reference
R10026051
Uniclima internal SKU
MPTARTE24
Brand
Beretta
Type of part
Pressure gauges & aquastats
Units in stock
4 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Pressure range
0-4 bar
Temperature range
0-120 °C
Before purchasing
  • The component code is also not available; it can only be verified by the internal reference R10026051.
Frequently asked questions

Frequently asked questions about the pressure gauge R10026051

Does this thermomanometer Ref. R10026051 work for a Beretta Quadra 24 IE FF?
Yes, the Quadra 24 IE FF is on the list of compatible boilers.
Does it also work for the Beretta Piramide Condens S 21?
Yes, the Piramide Condens S 21 appears on the compatibility list.
What does the thermomanometer of the Beretta Arte N measure?
Simultaneously measure the pressure (0-4 bar) and the flow temperature (0-120°C) using two copper capillaries at the rear.
When should the thermomanometer of the Beretta Quadra 20 IE be replaced?
The technical diagnosis must confirm that it is necessary to replace it, even when the needle does not move, is stuck, or the reading does not match the actual pressure of the system.
Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Beretta Thermohydrometer Pressure Temperature Arte 24 CAI Ref. R10026051