Biasi Biasi Pressure Gauge 24S Ref. BI1475108

Biasi Biasi Pressure Gauge 24S Ref. BI1475108

Stock · 3 units

Biasi Manaut Thermomanometer 24S Ref. BI1475108 is a manometer that measures and controls the pressure and temperature of the boiler circuit. When it fails, it may display incorrect readings, causing the boiler to lock out due to a false pressure drop or not properly regulate the temperature. This component is compatible with boilers from the MINOX range, such as MINOX and MINOX ECO, among others. It is recommended to replace it when these anomalies in its operation are detected.

VAT included

Compatibility

Biasi boilers compatible with reference BI1475108

Pressure gauge with reference BI1475108. Two confirmed compatibilities: MINOX and MINOX ECO.

Proven compatibility

Boiler modelFamilyVerification
Biasi MINOXMINOXContrasted
Biasi MINOX ECOMINOXContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. BI1475108 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference BI1475108. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the manometer BI1475108 resolves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure needle does not move no matter how much you open the filling valve.

    Cause: The internal mechanism of the thermometer-manometer has seized and no longer transmits the actual circuit pressure to the dial.

    Bleed a radiator and check if you feel resistance or if water comes out; if the circuit does have pressure, the fault is in the part and not in the system.

  • 02

    The temperature needle always shows the same value, whether the boiler is on or off.

    Cause: The thermomanometer combines two mechanisms in one dial, and the temperature mechanism can get stuck without the pressure mechanism failing.

    Carefully touch the flow and return pipes with the boiler running; if they vary in temperature and the needle does not, the problem is with the part.

  • 03

    The reading cannot be trusted because the dial is fogged up or the glass appears cracked.

    Cause: Moisture has entered the body of the thermometer-manometer, or the glass has been damaged by an impact.

    Inspect for visible condensation inside the glass before considering the reading valid or lost.

  • 04

    The pressure reading does not match what the boiler itself indicates or what you expect after refilling the circuit.

    Cause: The mechanism of the thermometer-manometer can drift over time and give a reading different from the actual pressure.

    Compare the reading of the gauge with how the boiler behaves (if it shuts off due to low pressure, for example) before replacing the part.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Biasi BI1475108 pressure gauge datasheet

Catalogue reference
BI1475108
Brand
Biasi
Type of part
Pressure gauges & aquastats
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Temperature range
0-120 °C
Pressure range
0-4 bar
Printed code (possible manufacturing date)
02/08 C
Frequently Asked Questions

Frequently asked questions about the pressure gauge BI1475108

What pressure and temperature range does the Biasi Manaut Manometer 24S Ref. BI1475108 measure?
Measures from 0 to 4 bar of pressure and from 0 to 120°C of temperature, combined in a single gauge.
Is this MB24S manometer compatible with the MINOX range?
Yes, the MB24S thermometer is compatible with the models from the MINOX range: MINOX and MINOX ECO.
When should I replace the Biasi Manaut Manómetro 24S pressure gauge?
You should change it when the needle does not move, the reading does not match the actual one, or the dial appears broken or fogged.
How many models are compatible with the Biasi Manaut Manómetro 24S pressure gauge?
The thermomanometer is compatible with a total of 2 confirmed models.
What fault codes does the Biasi Manaut Manómetro 24S pressure gauge have?
There are no documented fault codes.

Spare parts related to Biasi MINOX

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Biasi Biasi Pressure Gauge 24S Ref. BI1475108