Chaffoteaux Centora 2 24 FF Pressure Gauge Ref. 61303158
The Chaffoteaux Centora 2 24 FF pressure gauge, with reference 61303158, measures and controls the pressure of the boiler circuit. If it fails, it may display incorrect readings, which can cause the boiler to lock out due to a false low pressure or not regulate the temperature properly. This pressure gauge is compatible with several models, including the Centora 2.24 FF, Centora 2.28 FF, Centora 2.24 CF, among others. It is recommended to replace it when the readings are incorrect or when you notice a malfunction in the boiler.
VAT included
Consult via WhatsAppChaffoteaux boilers compatible with reference 61303158
Pressure gauge with reference 61303158. Ten confirmed compatibilities: Centora 2.24 FF and Centora 2.28 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Chaffoteaux Centora 2.24 FF | Centora | Contrasted |
| Chaffoteaux Centora 2.28 FF | Centora | Contrasted |
| Chaffoteaux Centora 2.24 CF | Centora | Contrasted |
| Chaffoteaux Centora 2.28 CF | Centora | Contrasted |
| Chaffoteaux Centora Green 2.24 FF | Centora Green | Contrasted |
| Chaffoteaux Aludra Delta 24 CF | Aludra Delta | Contrasted |
| Chaffoteaux Aludra Delta 24 FF | Aludra Delta | Contrasted |
| Chaffoteaux Aludra Delta 28 CF | Aludra Delta | Contrasted |
| Chaffoteaux Aludra Delta 28 FF | Aludra Delta | Contrasted |
| Chaffoteaux Calydra Green 24 | Calydra Green | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the ref. 61303158 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 61303158. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the manometer 61303158 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The temperature gauge does not move, even though the heating water is hot.
Cause: The copper capillary that carries the temperature signal is broken or has lost the fluid.
Check the capillary path for a closed bend or a crushed point before declaring the part as broken.
- 02
The pressure gauge remains fixed at the same value, regardless of what happens in the circuit.
Cause: The pressure mechanism of the manometer has seized, regardless of the temperature mechanism.
Bleed a radiator or add water to create a real pressure change and check if the pressure gauge reacts.
- 03
There is a water leak at the fitting where the part screws into the boiler.
Cause: The sealing gasket of the threaded fitting has degraded with use.
Tighten the fitting carefully and check both when cold and hot if the dripping stops before replacing the entire part.
- 04
The copper capillary is bent or crushed at some point along its path.
Cause: A damaged capillary does not transmit the fluid pressure properly and distorts or nullifies the temperature reading.
Follow the capillary path to the sensor to locate the damaged point before deciding whether it is necessary to replace the part.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the Chaffoteaux pressure gauge 61303158
- Catalogue reference
- 61303158
- Brand
- Chaffoteaux
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days