Pressure Gauge Boiler Victoria 24/24 F / Neobit S 24/24 F - Ref. 125892245

Pressure Gauge Boiler Victoria 24/24 F / Neobit S 24/24 F - Ref. 125892245

The pressure gauge for the Victoria 24/24 F / Neobit S 24/24 F boiler measures and controls the water circuit pressure. If this part fails, you may notice incorrect readings, which can cause the boiler to lock out due to a false lack of pressure or not regulate the temperature properly. This pressure gauge is compatible with several boilers, such as Neobit S 24/24 F, Novanox Platinum 24/24 F, Altais 24/24 F, and Platinum 24/24 F, among others. A technician should confirm through diagnosis whether it needs to be replaced when you observe issues with pressure or temperature regulation.

Catalogue reference
125892245
Warranty
1 year
VAT includedStock · 3 units
Compatibility

Baxi Roca boilers compatible with reference 125892245

Pressure gauge with reference 125892245. Four confirmed compatibilities: Neobit S 24/24 F and Novanox Platinum 24/24 F.

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca Neobit S 24/24 FNeobit SContrasted
Baxi Roca Novanox Platinum 24/24 FNovanoxContrasted
Baxi Roca Altais 24/24 FAltaisContrasted
Baxi Roca Platinum 24/24 FPlatinumContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 125892245 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 125892245. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the manometer 125892245

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The pressure gauge remains stuck at the same reading, it doesn't respond even if the circuit pressure changes.

    Cause: The internal mechanism seizes up over time, or the duct connecting it to the circuit becomes clogged with limescale.

    Drain some water through the bleed valve of a radiator and check if the needle moves before replacing it.

  • 02

    The pressure gauge shows a pressure that doesn't match what the boiler is actually doing.

    Cause: When the connection duct is partially blocked, the needle lags behind the actual pressure of the circuit.

    Compare the reading with the actual behavior of the boiler (if it resets when refilled, if it warns of low pressure) before relying solely on the needle.

  • 03

    Water is leaking where the pressure gauge connects to the pipe.

    Cause: The gasket or the threading of the fitting loses its seal with the heating and cooling cycles of the circuit.

    Check with dry paper if the leak is coming from the fitting or a nearby pipe before replacing the pressure gauge.

  • 04

    The dial appears broken, scratched, or foggy inside, and the scale is not visible.

    Cause: A blow or moisture entering through the glass seal leaves the interior damaged or fogged up.

    This symptom may be related to the part, but it does not confirm that it is faulty. A technician must check the equipment and its inspection according to the manual before deciding on a repair or replacement.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for Baxi Roca pressure gauge 125892245

Catalogue reference
125892245
Uniclima internal SKU
MPRV2424F
Brand
Baxi Roca
Type of part
Pressure gauges & aquastats
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Part reference
125892245
Pressure range
0-4 bar
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure gauge 125892245

Is this pressure gauge suitable for both the Victoria 24/24 F and the Neobit S 24/24 F?
Yes, it is indicated as compatible with both models.
What pressure range does the pressure gauge of the Victoria 24/24 F indicate?
According to the photographed gauge, it measures from 0 to 4 bar.
How do I check if reference 125892245 corresponds to my pressure gauge?
The code 125892245 is marked on the part itself, so just check it on the casing.
What symptoms indicate that the pressure gauge of the Victoria 24/24 F needs to be replaced?
That the needle doesn't move, that it shows a pressure that isn't real, or that it leaks from the connection fitting.
Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Pressure Gauge Boiler Victoria 24/24 F / Neobit S 24/24 F - Ref. 125892245