Pressure gauge Manaut GLM4 16
The Manaut GLM4 16 manometer is a device that measures and controls the pressure or temperature of the boiler circuit. If it malfunctions, you will notice incorrect readings, which can cause the boiler to lock out due to a false low pressure or not regulate the temperature properly. This manometer is compatible with boilers from the Manaut brand, such as the GLM4 16 model, among others. A technician must confirm through diagnosis whether it needs to be replaced when it starts showing erroneous readings or does not function correctly.
- Type of part
- Pressure gauges & aquastats
- Status
- Refurbished
- internal SKU
- MCMGLM16
- Warranty
- 1 year
Compatible Manaut boilers
Manometer. A proven compatibility: GLM4 16.
Verified compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Biasi GLM4 16 | Manaut | Verified |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the manometer
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The pressure gauge is not showing anything; it seems to be malfunctioning.
Cause: The internal mechanism of the pressure gauge has broken and is not sending a signal.
Check for any visible bends or breaks in the capillary before considering the part to be damaged.
- 02
The needle stays fixed at a number even though the boiler changes.
Cause: The internal mechanism has become blocked and does not detect the changes.
Turn the boiler on and off several times and observe if the needle moves; if it doesn't move, confirm the fault.
- 03
Water is leaking from the connection of the pressure gauge fitting.
Cause: The gasket of the fitting has deteriorated due to heat and cold.
Tighten the fitting with a wrench and dry the area well; if there is moisture again soon, the leak is from the fitting or the part.
- 04
The pressure is reading correctly, but the temperature is not changing.
Cause: The temperature bulb is independent and can fail without affecting the pressure.
Check that the temperature bulb is properly positioned in its sleeve before replacing the entire pressure gauge.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Manaut pressure gauge data sheet
- Uniclima internal SKU
- MCMGLM16
- Brand
- Manaut
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Pressure gauge
- 0-4 bar
- Temperature scale
- approximately 30-110 °C (marks 50, 70, and 90 visible; extremes partially covered by the pressure window)