Pressure Gauge Ferroli Divatop HF 24 Ref. 39818210
The Ferroli Divatop HF 24 Pressure Gauge Ref. 39818210 is a device that measures and controls the pressure in the boiler circuit. If this part fails, you will notice incorrect readings, which can cause the boiler to lock out due to a false low pressure or not regulate the temperature properly. It is compatible with boilers from the Divatop, Domicompact, Domiproject, Divatech, Ferdigit, and Econcept/Bluehelix ranges, among others. It is recommended to replace the pressure gauge when you notice that the readings are unreliable or if the boiler is experiencing operational issues related to pressure.
VAT included
Consult via WhatsAppFerroli boilers compatible with reference 39818210
Pressure gauge with reference 39818210. 25 verified compatibilities: Divatop H F24 and Divatop HF 24.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ferroli Divatop H F24 | Divatop | Contrasted |
| Ferroli Divatop HF 24 | Divatop | Contrasted |
| Ferroli Divatop H F30 | Divatop | Contrasted |
| Ferroli Divatop Low NOx F24 | Divatop | Contrasted |
| Ferroli Divatop Low NOx F32 | Divatop | Contrasted |
| Ferroli Domicompact F24 | Domicompact | Contrasted |
| Ferroli Domicompact F30 | Domicompact | Contrasted |
| Ferroli Domicompact C24 | Domicompact | Contrasted |
| Ferroli Domicompact C30 | Domicompact | Contrasted |
| Ferroli Domiproject F24 | Domiproject | Contrasted |
| Ferroli Domiproject F32 | Domiproject | Contrasted |
| Ferroli Domiproject D F24 | Domiproject | Contrasted |
| Ferroli Domiproject D F32 | Domiproject | Contrasted |
| Ferroli Divatech F24 | Divatech | Contrasted |
| Ferroli Divatech F32 | Divatech | Contrasted |
| Ferroli Divatech Micro F24 | Divatech | Contrasted |
| Ferroli Divatech Micro F32 | Divatech | Contrasted |
| Ferroli Ferdigit C24 | Ferdigit | Contrasted |
| Ferroli Ferdigit F24 | Ferdigit | Contrasted |
| Ferroli Ferdigit Micro C24 | Ferdigit | Contrasted |
| Ferroli Econcept Tech 25C | Econcept / Bluehelix (condensation) | Contrasted |
| Ferroli Econcept Tech 35C | Econcept / Bluehelix (condensation) | Contrasted |
| Ferroli Bluehelix Pro 25C | Econcept / Bluehelix (condensation) | Contrasted |
| Ferroli Bluehelix Pro 32C | Econcept / Bluehelix (condensation) | Contrasted |
| Ferroli Bluehelix Tech | Econcept / Bluehelix (condensation) | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if ref. 39818210 is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference 39818210. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure gauge 39818210 resolves.
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The needle remains fixed even when the circuit pressure changes.
Cause: The internal mechanism is stuck and does not respond to pressure changes.
Bleed a radiator and check if the overall pressure drops in the boiler; if the needle does not move, the fault is with the pressure gauge.
- 02
It doesn't show pressure when refilling or bleeding the circuit, as if it were disconnected.
Cause: The passage to the mechanism is blocked, usually due to scale buildup in the connection.
Open the filling valve for a moment and check if you notice real pressure through another means before considering the pressure gauge as faulty.
- 03
The pressure indicated does not match what it should be according to the installation.
Cause: The internal spring loses calibration over time and the reading is no longer reliable even though the needle moves.
Compare with the pressure displayed on the boiler, if available, before replacing the pressure gauge.
- 04
The dial or the glass is broken or scratched, and the scale cannot be read properly.
Cause: A blow during maintenance or assembly damages the plastic casing, which cannot withstand impacts.
Check that the glass is intact on the outside; if it's just dirty, sometimes carefully cleaning it is enough.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Ferroli 39818210 pressure gauge datasheet
- Catalogue reference
- 39818210
- Brand
- Ferroli
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 3 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Pressure gauge
- 0-4 bar
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ferroli Divatop HF 24 Manual (PDF)Document © Ferroli, provided as a technical reference.