Pressure gauge Junkers Eurostar ACU HIT ZWSE 28 4 MFA Ref. 87167618750

Pressure gauge Junkers Eurostar ACU HIT ZWSE 28 4 MFA Ref. 87167618750

Stock · 1 unit

The Junkers Eurostar ACU HIT ZWSE 28 4 MFA manometer is a device that measures and controls the pressure of the boiler circuit. Its function is essential to ensure that pressure and temperature are maintained at the appropriate levels. When it fails, you will notice incorrect readings, which can cause the boiler to lock out due to a false lack of pressure or not regulate the temperature properly. This manometer is compatible with boilers from the Eurostar ACU HIT range and specific models of Cerastar B50 ZWSE, among others. It is recommended to replace it when you experience those symptoms of malfunction.

VAT included

Compatibility

Junkers boilers compatible with reference 87167618750

Pressure gauge with reference 87167618750. Four confirmed compatibilities: Cerastar B50 ZWSE 23-4 MFA and Cerastar B50 ZWSE 23-4 MFK.

Proven compatibility

Boiler modelFamilyVerification
Junkers Cerastar B50 ZWSE 23-4 MFACerastar B50 ZWSEContrasted
Junkers Cerastar B50 ZWSE 23-4 MFKCerastar B50 ZWSEContrasted
Junkers Cerastar B50 ZWSE 28-4 MFACerastar B50 ZWSEContrasted
Junkers Eurostar ACU HIT ZWSE 28-4 MFAEurostar ACU HIT ZWSEContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 87167618750 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 87167618750. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the manometer 87167618750 solves.

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The needle is outside the green zone even though you have replenished pressure in the circuit.

    Cause: The mechanism may be misaligned and no longer indicates the same as the actual pressure of the system.

    Compare the reading with the feel of the filling valve or with a portable manometer if you have one.

  • 02

    The pressure gauge does not move or gets stuck regardless of what happens with the installation.

    Cause: The internal shaft seizes over the years and stops transmitting any pressure changes.

    Bleed a radiator and check if the needle follows the drop; if nothing moves, the fault is in the pressure gauge.

  • 03

    The reference green zone is not distinguishable due to wear on the glass or the dial.

    Cause: The plastic of the glass becomes opaque with heat and time, covering the colored strip that indicates the correct range.

    With good light or a flashlight, check if it is at least possible to see whether the needle is to the left or right of the green band.

  • 04

    The boiler is losing pressure and you need to check it visually.

    Cause: A reliable manometer is the reference to know if it is really necessary to refill water or if the problem is something else.

    Mark the current reading and check it a few hours later; if it decreases steadily, there is a real leak, not just a faulty pressure gauge.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Junkers pressure gauge 87167618750

Catalogue reference
87167618750
Brand
Junkers
Type of part
Pressure gauges & aquastats
Units in stock
1 unit
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Pressure gauge
0-4 bar, green zone approximately 1-2.5 bar
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure gauge 87167618750

Is this manometer suitable for the Junkers Cerastar ZWSE 28-4 MFA?
Yes, it is on the list of compatible boilers in this document, along with ZWSE 23-4 MFA/MFK and ZWSE 28-4 MFK.
What green zone does the manometer of the Cerastar B50 ZWSE 23 indicate?
The scale ranges from 0 to 4 bar, with a green reference zone approximately between 1 and 2.5 bar.
Is this manometer also suitable for the Cerastar B50 ZWSE 28?
Yes, that boiler is on the list of compatible models in this document.

Spare parts related to Junkers Cerastar B50 ZWSE

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Pressure gauge Junkers Eurostar ACU HIT ZWSE 28 4 MFA Ref. 87167618750