Temperature Indicator Renova Micra 23 SE
If you notice incorrect temperature readings or issues with the regulation of the boiler, a technical diagnosis must confirm whether you need the Temperature Indicator Renova Micra 23 SE. This part measures and controls the temperature of your boiler's circuit, ensuring its proper operation. When it fails, the boiler may lock out due to a false lack of pressure, causing inconveniences in its performance. It is compatible with models from the HABITAT range, such as the 2 E and the 23 SE, and from the MICRA range, such as the 23 SE and the 28 SE, among others. A technician must confirm through diagnosis whether it needs to be replaced when you start to notice these symptoms.
- Type of part
- Pressure gauges & aquastats
- Status
- Refurbished
- internal SKU
- MTRM23SE
- Warranty
- 1 year
Compatible Renova boilers
Manometer. Four confirmed compatibilities: 2 E and 23 SE.
Verified compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Renova 2 E | HABITAT | Verified |
| Renova 23 SE | HABITAT | Verified |
| Renova 23 SE | MICRA | Verified |
| Renova 28 SE | MICRA | Verified |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
The part reference, model, and equipment revision must be verified against the manufacturer's documentation.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms that require diagnosis on the manometer
The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The indicator does not show temperature, the needle does not move even though the boiler is hot.
Cause: The internal mechanism that moves the needle may be blocked or have lost its seal, preventing it from reflecting temperature changes.
Check that the indicator sensor is properly positioned in its housing and has not shifted before replacing the part.
- 02
The dial is broken, scratched, or so dirty that the needle cannot be seen.
Cause: The protective glass of the gauge can crack due to impacts or prolonged vibrations from the boiler, without affecting the internal mechanism.
Check if the damage is only to the outer glass: if the needle moves normally when touching the boiler, the problem is aesthetic and you do not need to replace the entire indicator.
- 03
You don't know if there is a risk of frost in the circuit because the indicator does not show low temperatures.
Cause: The red arc from 0-20 °C is designed to warn of that risk; if the needle does not move in that range even though the room is cold, the instrument is not functioning properly.
On a cold day, compare the reading of the gauge with the actual ambient temperature: if the needle does not move or enter the red zone, the fault is with the gauge, not the installation.
- 04
The needle moves but gets stuck at a point and does not advance further.
Cause: The needle shaft may be rubbing against the dial or the glass, or the internal mechanism may have seized up over time.
Gently tap the glass while the boiler is running: if the needle releases and moves, it is a mechanical jam; if it does not react, the mechanism is blocked.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Renova pressure gauge data sheet
- Uniclima internal SKU
- MTRM23SE
- Brand
- Renova
- Type of part
- Pressure gauges & aquastats
- Units in stock
- 6 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Part data and available documentation
Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.
- Temperature scale
- 0-120 °C, with a red arc in the range 0-20 °C (likely warning zone for freezing risk)
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Renova 23 SE Manual (PDF) Document © Renova, provided as a technical reference.