If you notice incorrect readings in the pressure or temperature of your boiler, a technical diagnosis should confirm if you need a Wolf GG EK 24 Thermometer. This manometer measures and controls the pressure and temperature of the circuit, ensuring proper operation. When it fails, the boiler may lock due to a false lack of pressure or may not regulate the temperature properly. It is compatible with several models, including GG-1E, GG-1EK, GG-E, GG-EK, GU-1E, GU-1EK, GU-E, and GU-EK, among others. A technician should confirm through diagnosis if it needs to be replaced when it starts giving incorrect readings.

Catalogue reference
2039065
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Wolf boilers compatible with reference 2039065

Pressure gauge with reference 2039065. Nine confirmed compatibilities: GG-1E and GG-1EK.

Verified compatibility

Boiler modelFamilyVerification
Wolf GG-1EGG-1EVerified
Wolf GG-1EKGG-1EKVerified
Wolf GG-EGG-EVerified
Wolf GG-EKGG-EKVerified
Wolf GU-1EGU-1EVerified
Wolf GU-1EKGU-1EKVerified
Wolf GU-EGU-EVerified
Wolf GU-EKGU-EKVerified
Wolf 120/120SWVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the reference 2039065 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 2039065. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis on the manometer 2039065

The manometer shows the pressure of the boiler circuit. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The needle does not move even if you bleed or refill water.

    Cause: The internal Bourdon tube gets clogged over time and with scale from the circuit, preventing it from moving with pressure changes.

    Fill the circuit a little and wait half a minute; if the needle does not move even a millimeter, the pressure gauge is not transmitting the pressure.

  • 02

    Water is leaking from the base of the pressure gauge.

    Cause: The brass fitting loosens or the internal gasket dries out over time, allowing water to pass through.

    Gently tighten the fitting by hand and check if the drop disappears; if it continues to drip after tightening, the internal gasket is no longer sealing.

  • 03

    The pressure is not clearly visible because the needle covers the scale.

    Cause: In this series, the lower range of the scale is covered by the needle at rest, which can cause confusion.

    Check the usual working pressure of the boiler before evaluating the reading and compare it with the pressure of the furthest radiator.

  • 04

    The pressure rises when heating and does not drop completely when cooling.

    Cause: If the manometer is stuck, it may remain fixed at a high reading and not reflect the actual drop in pressure as it cools down.

    Note the pressure in cold and hot during two cycles; if the needle never returns to the same point in cold, suspect the pressure gauge before the expansion vessel.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Wolf 2039065 pressure gauge.

Catalogue reference
2039065
Uniclima internal SKU
MPWGG24
Brand
Wolf
Type of part
Pressure gauges & aquastats
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

Pressure scale range
0-4 bar (the minimum value is obscured by the needle in the photo)
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the pressure gauge 2039065

Is this part for the Wolf GG-1E a thermometer or a manometer?
It is a manometer: the visible scale on the part is in bar, although the catalog referred to it as a thermometer.
Is this manometer suitable for the Wolf SW 120/120 boiler?
Yes, it is compatible with the Wolf SW 120/120 as well as with the indicated GG and GU series.
Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Wolf GG EK 24 Thermometer Ref. 2039065