Pressure Sensor Baxi Roca Victoria 24 24 F Ref. 125568703

Pressure Sensor Baxi Roca Victoria 24 24 F Ref. 125568703

The pressure sensor Baxi Roca Victoria 24 24 F is a sensor that measures the water pressure in the heating circuit and sends this information to the control board. If it fails, you may notice incorrect readings and lockouts due to low pressure, which can generate fault codes such as E10 or E164. This sensor is compatible with models from the Victoria range, as well as others like Neobit, Bios, Novanox, Novamax, and Neodens, among others. It is usually replaced when it shows measurement failures or causes problems in the operation of the boiler.

Type of part
Pressure sensors
Catalogue reference
125568703
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Baxi Roca boilers compatible with reference 125568703

Pressure sensor with reference 125568703. 12 verified compatibilities: VICTORIA 24/24 and VICTORIA 24/24 F.

Verified compatibility

Boiler modelFamilyVerification
Baxi Roca VICTORIA 24/24VICTORIAVerified
Roca Victoria 24/24 FVICTORIAVerified
Baxi Roca NEOBIT PLUS 24/24FNEOBITVerified
Baxi Roca NEOBIT S 24/24FNEOBITVerified
Baxi Roca BIOS 85 FBIOSVerified
Baxi Roca BIOS 100 FBIOSVerified
Baxi Roca NOVANOX 24/24FNOVANOXVerified
Baxi Roca NOVANOX 28/28FNOVANOXVerified
Baxi Roca NOVAMAX 31NOVAMAXVerified
Baxi Roca NEODENS 24/24FNEODENSVerified
Baxi Roca NEODENS 28/28FNEODENSVerified
Baxi Roca ALTAIS 24/24FALTAISVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 125568703 is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 125568703. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch 125568703

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The display shows a pressure different from that of the installation's manometer.

    Cause: The sensor sends an incorrect pressure signal to the PCB, and the control unit relies on that data.

    Compare the reading on the screen with an external manometer placed at the same point in the circuit before considering that the part is defective.

  • 02

    The boiler locks out due to low pressure even though the circuit is full.

    Cause: If the signal from the sensor decreases or becomes unstable, the control unit interprets that there is a lack of water and turns off the equipment for safety.

    Bleed the air from the circuit and check that the actual pressure is between 1 and 1.5 bar before changing the sensor.

  • 03

    The pump does not modulate correctly, it always operates at maximum speed or does not respond to changes in demand.

    Cause: In systems with a modulating pump, the electronics adjust the speed according to the signal from the sensor, and incorrect data affects that regulation.

    Observe if the behavior of the pump changes when adjusting the actual pressure of the circuit with the filling valve.

  • 04

    The pressure warning or the fault code appears and disappears without a clear pattern.

    Cause: A loose contact or wiring in the sensor causes an intermittent signal that the PCB interprets as a real anomaly.

    Check the connector of the sensor and the wiring up to the PCB before replacing the part.

Fault codes Roca that require diagnosis

CodeFaultTechnical checks
E10The hydraulic pressure switch does not confirm operation (lack of pressure in the heating circuit).If the pressure sensor/pressure switch (125568703) does not detect the correct pressure and does not close, the PCB does not enable the boiler and E10 appears; check the actual pressure on the manometer (≈0.7–1.5 bar when cold) and the switching/wiring of the pressure switch (>~0.5 bar).
E164Lack of switching/consensus of the hydraulic differential pressure switch.In BIOS, the differential pressure sensor does not change state even though there is pressure/flow (damaged membrane/micro), so the electronics do not receive consensus; check pressure and continuity of the pressure switch during demand and replace if it does not switch with correct values.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Pressure switch data sheet Baxi Roca 125568703

Catalogue reference
125568703
Uniclima internal SKU
PSRV2424F
Brand
Roca
Type of part
Pressure sensors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently asked questions

Frequently asked questions about the pressure sensor 125568703

Does this pressure switch work for the Baxi Roca Victoria 24/24?
Yes, the Victoria 24/24 is on the list of compatible boilers in this document.
What fault does this sensor resolve in a Novanox 24/24F?
It should be checked when the equipment stops reading the pressure of the installation correctly. Replacement requires a technical diagnosis.
Does this same sensor work for the Neobit Plus 24/24F and the Neodens 24/24F?
Yes, both models are on the list of compatible boilers in this document.
Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Pressure Sensor Baxi Roca Victoria 24 24 F Ref. 125568703