Pressure Sensor Manaut Myto Condens 24 Ref. BI1441104

Pressure Sensor Manaut Myto Condens 24 Ref. BI1441104

If your boiler experiences unexpected blockages or incorrect pressure readings, a technical diagnosis must confirm if you need the Pressure Sensor Biasi Myto Condens 24 Ref. BI1441104. This sensor measures the water circuit pressure and sends the information to the control board. When it fails, it can cause issues in the boiler's operation due to incorrect readings. This sensor is compatible with several models in the Biasi range, such as the Myto Condens 24, among others. A technician must confirm through diagnosis if it is necessary to replace this part when the mentioned symptoms are detected.

Type of part
Pressure sensors
internal SKU
SPMMC24
Warranty
1 year
VAT included Stock · 7 units
Compatibility

Compatible Manaut boilers

Pressure sensor. 11 verified compatibilities: MIDAS 24E and MIDAS 28E.

Verified compatibility

Boiler modelFamilyVerification
Biasi MIDAS 24EMANAUTVerified
Biasi MIDAS 28EMANAUTVerified
Biasi MIDAS 32EMANAUTVerified
Biasi MIDAS ECO 24EMANAUTVerified
Biasi MIDAS ECO 28EMANAUTVerified
Biasi MYTO CONDENS 24MANAUTVerified
Biasi MYTO CONDENS 35MANAUTVerified
Biasi MYTO CONDENS INOX 24MANAUTVerified
Biasi MYTO CONDENS INOX 35MANAUTVerified
Biasi MYTO CONDENS PLUS 24MANAUTVerified
Biasi MYTO CONDENS PLUS 35MANAUTVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler shows a water pressure or filling error, even though the circuit has the correct pressure.

    Cause: The sensor converts the water pressure into an electrical signal; if this signal is incorrect, the control board thinks that there is a lack of water and locks the boiler.

    Measure the pressure at the filling tap or on an external manometer and compare it with the reading from the boiler before changing the sensor.

  • 02

    The pressure readings on the display change by themselves, without anyone having touched the filling.

    Cause: A damaged sensor produces an unstable signal, causing fluctuations in the display readings.

    Check if there is a slow leak in the circuit that could explain the variations before thinking that the problem is the sensor.

  • 03

    The boiler does not start and remains on standby, without initiating the heating cycle.

    Cause: If the signal from the sensor is outside the range expected by the control board, it does not allow ignition for safety reasons in case of a possible lack of water.

    Check the connector of the sensor and make sure there is no moisture or corrosion on the pins before replacing it.

  • 04

    The digital manometer of the boiler remains fixed at a value and does not react when bleeding or filling the circuit.

    Cause: When the sensor stops transmitting real pressure changes, the reading freezes even though the water in the circuit changes.

    Bleed a radiator and check if the reading changes; if nothing changes, the sensor is more likely to be faulty than the circuit.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Pressure switch data sheet Biasi

Uniclima internal SKU
SPMMC24
Brand
Manaut
Type of part
Pressure sensors
Units in stock
7 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently asked questions

Frequently asked questions about the pressure switch

Does this pressure switch work for the Biasi Midas 24E boiler?
Yes, Midas 24E is on the list of compatible boilers, along with Midas 28E, 32E, and the Eco versions.
Is it suitable for the Biasi Myto Condens 35?
Yes, it is compatible with Myto Condens 24 and 35, as well as the Inox and Plus versions.
Delivery calculated by destination Delivery time shown at checkout
1-year warranty inspected and tested
14-day return uninstalled parts
Technical support we verify your model
Pressure Sensor Manaut Myto Condens 24 Ref. BI1441104