Water Pressure Sensor Beretta Exclusive MIX 26 Ref. R10028142

Water Pressure Sensor Beretta Exclusive MIX 26 Ref. R10028142

Stock · 3 units

When you open the tap or start the heating, the Beretta Exclusive MIX 26 Water Pressure Sensor (Ref. R10028142) measures the pressure of the circuit and sends the information to the control board. If this sensor fails, you may notice incorrect readings, which can lead to lockouts due to false low pressure, generating fault code 42. This component is compatible with several Beretta boilers, such as the Exclusive 24 CAI, Exclusive Mix 26 CSI, and Kompakt 24 CAI, among others. It is advisable to replace it if you observe pressure issues or errors in operation.

VAT included

Compatibility

Beretta boilers compatible with reference R10028142

Pressure sensor with reference R10028142. 24 verified compatibilities: Exclusive 24 CAI and Exclusive 28 CAI.

Proven compatibility

Boiler modelFamilyVerification
Beretta Exclusive 24 CAIBerettaContrasted
Beretta Exclusive 28 CAIBerettaContrasted
Beretta Exclusive 28 RAIBerettaContrasted
Beretta Exclusive Mix 26 CSIBerettaContrasted
Beretta Exclusive Mix 30 CSIBerettaContrasted
Beretta Exclusive Mix 32 CSIBerettaContrasted
Beretta Exclusive Mix 35 CSIBerettaContrasted
Beretta Exclusive Green 16 RSIBerettaContrasted
Beretta Exclusive Green 25 CSIBerettaContrasted
Beretta Exclusive Green 25 RSIBerettaContrasted
Beretta Exclusive Green 35 CSIBerettaContrasted
Beretta Exclusive Green 35 RSIBerettaContrasted
Beretta Exclusive Boiler Green 30 BSIBerettaContrasted
Beretta Exclusive Boiler Green HE 25 BSIBerettaContrasted
Beretta Exclusive Boiler Green HE 35 BSIBerettaContrasted
Beretta Kompakt 24 CSIBerettaContrasted
Beretta Kompakt 24 CAIBerettaContrasted
Beretta Kompakt 28 CSIBerettaContrasted
Beretta Meteo Green 25 CSIBerettaContrasted
Beretta Meteo Green 30 CSIBerettaContrasted
Beretta Meteo Green 35 CSIBerettaContrasted
Beretta Meteo Green 25 RSIBerettaContrasted
Beretta Meteo Green 35 RSIBerettaContrasted
Beretta Power Green 50BerettaContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part R10028142 is the one for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10028142. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch R10028142 resolves.

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The display always shows the same pressure, it neither rises nor falls even if you refill or bleed water.

    Cause: The pressure sensor is stuck and does not send the actual value to the control board.

    Compare the reading on the screen with an analog manometer (the one from the bleed valve or the filling key) before changing the sensor.

  • 02

    The boiler locks out due to low pressure even though you see the circuit full and the physical manometer reads correctly.

    Cause: If the sensor sends a false low pressure value, the control board shuts off for safety even if the water is at the right temperature.

    Check that the tube or connection that carries the pressure to the sensor is not bent, blocked, or has an air bubble.

  • 03

    The pump and flame modulation are erratic, as if the boiler doesn't know if there is enough water.

    Cause: An unstable pressure signal from the sensor confuses the control board, which adjusts the boiler with incorrect data.

    Note if the fault coincides with knocks or vibrations in the piping: it could be a loose connection in the wiring of the sensor and not the part itself.

Fault codes for Beretta that this part resolves.

CodeFaultDiagnosis and solution
42Water pressure transducer fault.The R10028142 sensor delivers a null/out-of-range signal or does not reach the PCB (internal fault or wiring), so the electronics detect a transducer defect and display 42; check that the mechanical pressure gauge and display reading match and measure the power/signal of the sensor at its connector.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Pressure sensor data sheet Beretta R10028142

Catalogue reference
R10028142
Brand
Beretta
Type of part
Pressure sensors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

voltage
5-15V
power
4W
Frequently Asked Questions

Frequently asked questions about the pressure sensor R10028142

Is this collector suitable for the Beretta Kompakt 24 CAI?
Yes, it is among the listed compatible models, along with the Exclusive 24 CAI, 28 CAI, 28 RAI, Boiler Green 30 BSI, Green 35 RSI, Mix 26 CSI/AR, and Mix 30 CSI/AR.

Spare parts related to Beretta Beretta

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Water Pressure Sensor Beretta Exclusive MIX 26 Ref. R10028142