Water Pressure Sensor Beretta Exclusive MIX 26 Ref. R10028142

Water Pressure Sensor Beretta Exclusive MIX 26 Ref. R10028142

When you open the tap or start the heating, the Beretta Exclusive MIX 26 Water Pressure Sensor (Ref. R10028142) measures the pressure of the circuit and sends the information to the control board. If this sensor fails, you may notice incorrect readings, which can lead to lockouts due to a false lack of pressure, generating fault code 42. This component is compatible with several Beretta boilers, such as the Exclusive 24 CAI, Exclusive Mix 26 CSI, and Kompakt 24 CAI, among others. A technician should confirm through diagnostics whether it needs to be replaced if you observe pressure issues or errors in operation.

Type of part
Pressure sensors
Catalogue reference
R10028142
Warranty
1 year
VAT included Stock · 3 units
Compatibility

Beretta boilers compatible with reference R10028142

Pressure sensor with reference R10028142. 24 verified compatibilities: Exclusive 24 CAI and Exclusive 28 CAI.

Verified compatibility

Boiler modelFamilyVerification
Beretta Exclusive 24 CAIBerettaVerified
Beretta Exclusive 28 CAIBerettaVerified
Beretta Exclusive 28 RAIBerettaVerified
Beretta Exclusive Mix 26 CSIBerettaVerified
Beretta Exclusive Mix 30 CSIBerettaVerified
Beretta Exclusive Mix 32 CSIBerettaVerified
Beretta Exclusive Mix 35 CSIBerettaVerified
Beretta Exclusive Green 16 RSIBerettaVerified
Beretta Exclusive Green 25 CSIBerettaVerified
Beretta Exclusive Green 25 RSIBerettaVerified
Beretta Exclusive Green 35 CSIBerettaVerified
Beretta Exclusive Green 35 RSIBerettaVerified
Beretta Exclusive Boiler Green 30 BSIBerettaVerified
Beretta Exclusive Boiler Green HE 25 BSIBerettaVerified
Beretta Exclusive Boiler Green HE 35 BSIBerettaVerified
Beretta Kompakt 24 CSIBerettaVerified
Beretta Kompakt 24 CAIBerettaVerified
Beretta Kompakt 28 CSIBerettaVerified
Beretta Meteo Green 25 CSIBerettaVerified
Beretta Meteo Green 30 CSIBerettaVerified
Beretta Meteo Green 35 CSIBerettaVerified
Beretta Meteo Green 25 RSIBerettaVerified
Beretta Meteo Green 35 RSIBerettaVerified
Beretta Power Green 50BerettaVerified

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part R10028142 is the one for your boiler

The part reference, model, and equipment revision must be verified against the manufacturer's documentation.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference R10028142. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms that require diagnosis in the pressure switch R10028142

The pressure sensor measures the water pressure for the electronics. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The display always shows the same pressure, it neither rises nor falls even if you refill or bleed water.

    Cause: The pressure sensor is stuck and does not send the actual value to the control board.

    Compare the reading on the screen with an analog manometer (the one from the bleed valve or the filling key) before changing the sensor.

  • 02

    The boiler locks out due to low pressure even though you see the circuit full and the physical manometer reads correctly.

    Cause: If the sensor sends a false low pressure value, the control board shuts off for safety even if the water is at the right temperature.

    Check that the tube or connection that carries the pressure to the sensor is not bent, blocked, or has an air bubble.

  • 03

    The pump and flame modulation are erratic, as if the boiler doesn't know if there is enough water.

    Cause: An unstable pressure signal from the sensor confuses the control board, which adjusts the boiler with incorrect data.

    Note if the fault coincides with knocks or vibrations in the piping: it could be a loose connection in the wiring of the sensor and not the part itself.

Beretta fault codes that require diagnosis

CodeFaultTechnical checks
42Water pressure transducer fault.The R10028142 sensor delivers a null/out-of-range signal or does not reach the PCB (internal fault or wiring), so the electronics detect a transducer defect and display 42; check that the mechanical pressure gauge and display reading match and measure the power/signal of the sensor at its connector.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Pressure sensor data sheet Beretta R10028142

Catalogue reference
R10028142
Uniclima internal SKU
TPCEM26
Brand
Beretta
Type of part
Pressure sensors
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Part data and available documentation

Contrast the label codes, PCB, and revision with the installed part; they are not necessarily equivalent references.

voltage
5-15V
power
4W
Frequently asked questions

Frequently asked questions about the pressure sensor R10028142

Is this collector suitable for the Beretta Kompakt 24 CAI?
Yes, it is among the listed compatible models, along with the Exclusive 24 CAI, 28 CAI, 28 RAI, Boiler Green 30 BSI, Green 35 RSI, Mix 26 CSI/AR, and Mix 30 CSI/AR.
Delivery calculated by destination Delivery time shown at checkout