Air Pressure Switch Ariston AS 24 FF 65104671 01

Air Pressure Switch Ariston AS 24 FF 65104671 01

Stock · 2 units

If your boiler does not start or gets blocked despite the pressure seeming correct, you may need the Ariston AS 24 FF 65104671 01 air pressure switch. This part is responsible for monitoring the air pressure, allowing the boiler to operate properly. If it fails, you will notice that the boiler does not initiate the heating cycle. This pressure switch is compatible with several models, including those from the ALIXIA, ALTEAS, AS, BS, CLAS, and EGIS ranges, among others. It should be replaced when it shows faults in the operation of the boiler.

VAT included

Compatibility

Compatible Ariston boilers

Pressure switch. 14 confirmed compatibilities: 24 FF and X 24 FF.

Proven compatibility

Boiler modelFamilyVerification
Ariston 24 FFALIXIAContrasted
Ariston X 24 FFALTEASContrasted
Ariston 24 FFASContrasted
Ariston 24 FFBSContrasted
Ariston II 24 FFBSContrasted
Ariston 24 FFCLASContrasted
Ariston EVO 24 FFCLASContrasted
Ariston 24 FFEGISContrasted
Ariston PLUS 24 FFEGISContrasted
Ariston 24 FFGENUSContrasted
Ariston EVO 24 FFGENUSContrasted
Ariston 24 FFMATISContrasted
Ariston 25 FFPIGMAContrasted
Ariston 25 FFTALIAContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if it is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch resolves

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite and neither the fan nor the burner can be heard trying to start.

    Cause: If the pressure switch was already open before giving the command, the control board doesn't even start the ignition sequence.

    Check that power is reaching the boiler and that the fan is spinning freely before inspecting the pressure switch.

  • 02

    A ventilation fault code appears as soon as I try to turn it on.

    Cause: It is the usual response when the pressure switch does not close the contact that confirms the flue gas extraction.

    Check that the flue, being forced draft, is not blocked by nests, ice, or dirt.

  • 03

    The boiler works well in general but has more faults on very windy days.

    Cause: In forced draft equipment, the wind at the outlet can alter the pressure that the pressure switch detects and cause it to operate prematurely.

    Compare if the faults coincide with days of strong wind before replacing the part.

  • 04

    Upon opening the boiler, the silicone tubes of the pressure switch appear dry or cracked.

    Cause: Over the years, those tubes lose flexibility and allow air to enter, causing the pressure switch to stop reading the actual pressure.

    Check the condition of the silicone tubes of the pressure switch before declaring it faulty.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Ariston pressure switch datasheet

Brand
Ariston
Type of part
Pressure switches
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the pressure switch

Is this pressure switch suitable for the Ariston AS 24 FF?
Yes, it is listed for the AS 24 FF.
Does this pressure switch also work for the Ariston Alteas X 24 FF?
Yes, the Alteas X 24 FF is on the list of compatible boilers.
Is it also suitable for the Ariston Talia 25 FF?
Yes, the Talia 25 FF is listed in the compatibility list for this part.

Spare parts related to Ariston BS

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model