Air Pressure Switch Ariston AS 24 FF 65104671 01
If your boiler does not start or gets blocked despite the pressure seeming correct, you may need the Ariston AS 24 FF 65104671 01 air pressure switch. This part is responsible for monitoring the air pressure, allowing the boiler to operate properly. If it fails, you will notice that the boiler does not initiate the heating cycle. This pressure switch is compatible with several models, including those from the ALIXIA, ALTEAS, AS, BS, CLAS, and EGIS ranges, among others. It should be replaced when it shows faults in the operation of the boiler.
VAT included
Consult via WhatsAppCompatible Ariston boilers
Pressure switch. 14 confirmed compatibilities: 24 FF and X 24 FF.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Ariston 24 FF | ALIXIA | Contrasted |
| Ariston X 24 FF | ALTEAS | Contrasted |
| Ariston 24 FF | AS | Contrasted |
| Ariston 24 FF | BS | Contrasted |
| Ariston II 24 FF | BS | Contrasted |
| Ariston 24 FF | CLAS | Contrasted |
| Ariston EVO 24 FF | CLAS | Contrasted |
| Ariston 24 FF | EGIS | Contrasted |
| Ariston PLUS 24 FF | EGIS | Contrasted |
| Ariston 24 FF | GENUS | Contrasted |
| Ariston EVO 24 FF | GENUS | Contrasted |
| Ariston 24 FF | MATIS | Contrasted |
| Ariston 25 FF | PIGMA | Contrasted |
| Ariston 25 FF | TALIA | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if it is the part for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference —. If it is not visible, do not identify the part by its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch resolves
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and neither the fan nor the burner can be heard trying to start.
Cause: If the pressure switch was already open before giving the command, the control board doesn't even start the ignition sequence.
Check that power is reaching the boiler and that the fan is spinning freely before inspecting the pressure switch.
- 02
A ventilation fault code appears as soon as I try to turn it on.
Cause: It is the usual response when the pressure switch does not close the contact that confirms the flue gas extraction.
Check that the flue, being forced draft, is not blocked by nests, ice, or dirt.
- 03
The boiler works well in general but has more faults on very windy days.
Cause: In forced draft equipment, the wind at the outlet can alter the pressure that the pressure switch detects and cause it to operate prematurely.
Compare if the faults coincide with days of strong wind before replacing the part.
- 04
Upon opening the boiler, the silicone tubes of the pressure switch appear dry or cracked.
Cause: Over the years, those tubes lose flexibility and allow air to enter, causing the pressure switch to stop reading the actual pressure.
Check the condition of the silicone tubes of the pressure switch before declaring it faulty.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Ariston pressure switch datasheet
- Brand
- Ariston
- Type of part
- Pressure switches
- Units in stock
- 2 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Manuals and technical documentation
Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.
- Ariston X 24 FF Manual (PDF)Document © Ariston, provided as a technical reference.