Air Pressure Switch Baxi Roca Victoria 20 20 Huba Control Ref. 122161690

Air Pressure Switch Baxi Roca Victoria 20 20 Huba Control Ref. 122161690

Stock · 2 units

The air pressure switch Roca Baxi Victoria 20 20 Huba Control monitors the air pressure and authorizes the operation of the boiler. When it fails, the boiler may not start or may lock out, even if the actual pressure is correct. Users may experience fault codes such as 60-80-90, which indicate insufficient pressure, or 40-50-80-90 and 19, which signal pressure above zero. This pressure switch is compatible with several models from the Roca/Baxi Victoria 20/20 range, among others. It should be replaced when starting or locking issues are noticed in the boiler.

VAT included

Compatibility

Baxi Roca boilers compatible with reference 122161690

Pressure switch with reference 122161690. Four confirmed compatibilities: Victoria 20/20 and Victoria 20/20 F.

Proven compatibility

Boiler modelFamilyVerification
Baxi Roca Victoria 20/20Baxi Roca Victoria 20/20Contrasted
Baxi Roca Victoria 20/20 FBaxi Roca Victoria 20/20Contrasted
Baxi Roca Victoria 20/20 FFBaxi Roca Victoria 20/20Contrasted
Baxi Roca Victoria FBaxi Roca Victoria 20/20Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if ref. 122161690 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 122161690. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the pressure switch 122161690 resolves.

The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The boiler does not ignite: the fan starts but stops quickly.

    Cause: The pressure switch measures the depression of the extractor and, if it does not detect it, prevents ignition.

    Make sure the fan spins smoothly and without any strange noises before checking the pressure switch.

  • 02

    The boiler keeps locking out and needs to be reset several times a day.

    Cause: If the pressure switch does not switch properly, each ignition attempt may fail, even though the rest of the boiler operates well.

    Check the pressure intake pipes: make sure they are not damaged, fallen, or have condensation.

  • 03

    The problem started after cleaning the flue or the siphon.

    Cause: Any manipulation of the flue system can leave a pipe improperly positioned, which prevents the pressure switch from reading the pressure correctly.

    Check the pipe connections after any intervention in the duct before replacing the part.

Fault codes for Baxi Roca that this part resolves.

CodeFaultDiagnosis and solution
60-80-90Insufficient pressure in the pressure switch or flue thermostat.The air differential pressure switch does not close with the fan running (lack of depression/obstruction or fatigued diaphragm). Check that the tubes are crossed and clean, the operation of the extractor, and that the microcontact closes by applying slight depression while measuring continuity.
40-50-80-90Pressure above zero in the pressure switch or flue thermostat.The pressure switch appears closed at rest (membrane/micro stuck, tubes inverted or with condensates). Check that the contact is open with the boiler off, clean/dry connections and confirm switching by applying slight pressure/vacuum and measuring continuity.
19Pressure above zero in the pressure switch or flue thermostat.In boards with display (R/RS/Victoria FF family), the pressure switch remains "closed" without demand. Verify that the micro is open at rest, correctly check/invert the pneumatic connections, and rule out water/obstructions in the tubes.
20Insufficient pressure in the pressure switch or flue thermostat.On boards with a display, the pressure switch does not close when the fan starts (lack of draft/obstruction or pressure switch out of adjustment). Check the extractor, flue duct, and electrical closure of the pressure switch when generating depression; inspect crossed tubes and tightness.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Datasheet for pressure switch Baxi Roca 122161690

Catalogue reference
122161690
Brand
Baxi Roca
Type of part
Pressure switches
Units in stock
2 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Model printed on the label
VICTORIA F
Frequently Asked Questions

Frequently asked questions about the pressure switch 122161690

Is this air pressure switch compatible with the Baxi Roca Victoria 20/20 F boiler?
Yes, it is compatible with the Victoria 20/20 F, as well as with the Victoria 20/20, Victoria 20/20 FF, and Victoria F.
What fault does this pressure switch solve in a Victoria F boiler that does not ignite?
Correct the lockout due to lack of pressure: if the fan does not generate sufficient pressure, the boiler will not start, and this component is responsible for detecting that.
Does this pressure switch control air pressure or water pressure?
It controls the air depression generated by the fan before authorizing ignition, not the water pressure of the circuit.
How many models are compatible with this Roca Baxi air pressure switch?
It is compatible with a total of 4 models from the Roca/Baxi Victoria 20/20 range.
What is the reference for this air pressure switch?
The reference for this air pressure switch is PRECRV2020.
What fault codes are documented for this product?
The documented fault codes are: 60-80-90, 40-50-80-90, 19, and 20.