Pressure switch Boiler Renova Teknic F 23 E Ref. C6065FH1516
Pressure switch for Baxi Roca Renova Teknic F 23 E, with NC/NO/C contact micro switch. It cuts off or enables the operation of the boiler according to the detected pressure; in this unit, the setting is 0.48 mbar with a maximum of 6 mbar and powered at 250V~. It is replaced when the boiler does not ignite or shows a pressure switch fault.
VAT included
Consult via WhatsAppRenova boilers compatible with reference C6065FH1516
Pressure switch with reference C6065FH1516. A proven compatibility: Renova Teknic F 23 E.
Proven compatibility
| Boiler model | Family | Verification |
|---|---|---|
| Renova Renova Teknic F 23 E | Renova Teknic | Contrasted |
Can't see your model or have questions? The printed reference takes precedence. How to check it · Send us a photo via WhatsApp.
How to check if the part C6065FH1516 is the one for your boiler
What determines it is not the boiler model, but the reference printed on the part you already have installed.
- Find the reference printed on the installed part and check whether it matches the catalogue reference C6065FH1516. If it is not visible, do not identify the part from its shape alone.
- Check the full boiler model on its data plate and look for it in the model associations on this page.
- Compare the connections and physical body with the original part before installation.
- If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Symptoms and faults that the pressure switch C6065FH1516 resolves.
The pressure switch controls the air or water pressure to authorize operation. These are the typical symptoms and what to do:
Common symptoms and faults
- 01
The boiler does not ignite and shuts off immediately.
Cause: The air pressure switch does not detect the minimum pressure to allow the gas to flow, blocking the ignition.
Check that the flue duct is not blocked and that the extractor is functioning properly.
- 02
A fault code for the pressure switch or flue appears when trying to start.
Cause: The control board does not receive the signal from the pressure switch micro switch within the expected time.
Check the connection tubes of the pressure switch: make sure they are not loose, cracked, or have accumulated water.
- 03
The boiler starts, runs for a while, and then stops on its own without a clear pattern.
Cause: A worn microswitch can intermittently open the circuit, even if the pressure is correct.
Perform several consecutive ignition cycles and note whether the fault occurs consistently or only occasionally; this will help you identify if it is the pressure switch or the flue installation.
These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.
Data sheet for the pressure switch Renova C6065FH1516
- Catalogue reference
- C6065FH1516
- Brand
- Renova
- Type of part
- Pressure switches
- Units in stock
- 7 units
- Status
- Refurbished
- Warranty
- 1 year
- Shipping
- Delivery time shown at checkout
- Return
- 14 days
Data read on the part and in the manufacturer's documentation
What we have not been able to verify does not appear here.
- Nominal voltage
- 250V~
- Condenser
- 1.5(0.5) μF
- Set pressure
- 0.48 mbar
- Maximum pressure
- 6 mbar
- Batch code
- 0220F
- CE marking
- CE-0063AP3085/?
- Place of manufacture
- Made in China
- Contact settings
- NC/NO/C (microswitch)