3 Bar Safety Valve Ferroli Domi Project F 24 Ref. 39818270

3 Bar Safety Valve Ferroli Domi Project F 24 Ref. 39818270

Stock · 5 units

If you notice a constant water drip from your boiler, it may indicate that the Ferroli Domi Project F 24 3 Bar Safety Valve needs to be replaced. This valve is responsible for releasing water when the circuit pressure exceeds 3 bar, preventing damage to the system. It is compatible with several models, including Domiproject F24, Domicompact F24, and Divatop F24, among others. It should be replaced when it shows faults, such as continuous dripping or the inability to discharge properly.

VAT included

Compatibility

Ferroli boilers compatible with reference 39818270

Safety valve with reference 39818270. 22 verified compatibilities: Divatop C24 and Divatop C32.

Proven compatibility

Boiler modelFamilyVerification
Ferroli Divatop C24DivatopContrasted
Ferroli Divatop C32DivatopContrasted
Ferroli Divatop F24DivatopContrasted
Ferroli Divatop F32DivatopContrasted
Ferroli Divatop HF24DivatopContrasted
Ferroli Divatop HF32DivatopContrasted
Ferroli Divatop microDivatopContrasted
Ferroli Domiproject C24DomiprojectContrasted
Ferroli Domiproject C32DomiprojectContrasted
Ferroli Domiproject F24DomiprojectContrasted
Ferroli Domiproject F32DomiprojectContrasted
Ferroli Domiproject F24 DDomiprojectContrasted
Ferroli Domiproject F32 DDomiprojectContrasted
Ferroli Domicompact C24DomicompactContrasted
Ferroli Domicompact F24DomicompactContrasted
Ferroli Domicompact F30DomicompactContrasted
Ferroli Domicompact F24 DDomicompactContrasted
Ferroli Divatech CDivatechContrasted
Ferroli Divatech FDivatechContrasted
Ferroli Divatech DDivatechContrasted
Ferroli Bluehelix Tech ABluehelixContrasted
Ferroli Bluehelix Pro CBluehelixContrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the ref. 39818270 is the part for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference 39818270. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the safety valve 39818270 resolves.

The safety valve releases pressure when the circuit exceeds its setting. These are the typical symptoms and what to do:

Common symptoms and faults

  • 01

    The valve is continuously leaking from the discharge outlet, even when the boiler is turned off.

    Cause: The seat does not seal properly, usually due to dirt or limescale between the shutter and the seat.

    Move the bleed lever a couple of times to flush out the dirt and check if the dripping stops before replacing it.

  • 02

    The circuit needs to be filled at certain intervals, and no leaks can be found in the radiators or pipes.

    Cause: A slow and barely visible drip from the valve may be releasing pressure from the circuit without being noticeable at first glance.

    Place a dry piece of paper under the gas valve outlet for a day to confirm if there is moisture before looking for the leak in another area.

  • 03

    The lever of the gas valve is stuck and is difficult to move, or it does not budge at all.

    Cause: Corrosion or accumulated deposits can block the mechanism and leave the gas valve unable to act if the pressure rises.

    Try to move it carefully; if it doesn't budge, don't force it and keep in mind that it may not be protecting the installation.

  • 04

    In the first few days after filling the circuit, the gas valve drips; then it seems to calm down.

    Cause: An above-normal filling raises the pressure above the set point as soon as the boiler heats up, and the valve responds even if it is not faulty.

    Check the cold pressure after filling and adjust it to the value indicated by the boiler before suspecting the gas valve.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Ferroli safety valve 39818270

Catalogue reference
39818270
Brand
Ferroli
Type of part
Safety valves
Units in stock
5 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days

Data read on the part and in the manufacturer's documentation

What we have not been able to verify does not appear here.

Body material
Brass
Documentation

Manuals and technical documentation

Official documentation of the boiler, useful for locating the part and cross-referencing the fault codes.

Frequently Asked Questions

Frequently asked questions about the safety valve 39818270

Is this valve suitable for the Ferroli Domicompact F24?
Yes, the Domicompact F24 is among the indicated compatible models.
When should the safety valve of the Ferroli Bluehelix Pro C be replaced?
When it drips, it bleeds continuously or does not close after bleeding.
Does this valve work for the Ferroli Divatop HF24?
Yes, the Divatop HF24 is listed among the boilers compatible with this gas valve.
What is the reference for this safety valve?
The reference for this safety valve is VSMDPF24.
How many models are compatible with this gas valve?
This valve is compatible with a total of 22 models.
What pressure does this safety valve have?
This safety valve has a pressure of 3 Bar.