Repair and spare parts for Ariston boilers in Madrid

Specialized technical service for the entire Ariston range in Madrid. Repair of Clas EVO, Genus, Egis Plus, and Cares Premium boilers, with quick diagnostics and original spare parts.

💡 Direct response

Ariston is an Italian brand of Ariston Thermo Group, founded in 1930 in Fabriano (Ancona). It is one of the most important European manufacturers of heating and domestic hot water. Their boilers Clas EVO și Genus EVO condensing are popular in new Spanish constructions, while the ranges Egis Plus și Alteas they are still operational in many Madrid households.

🏆 Global Group

Ariston Thermo Group present in over 40 countries. Spare parts distribution network throughout Europe.

⚡ Condensation class A

Clas EVO and Genus EVO class A+. Smart connectivity via Ariston Net (Wi-Fi).

📦 Spare parts in stock

Original and OEM equivalents. Express shipping 24-48h throughout Spain.


Ariston product range

Condensing boilers

  • Clas EVO – A+ class combi condensing, aluminium heat exchanger. Most installed current range in new construction.
  • Clas System EVO – condensing heating only, for systems with external DHW tank.
  • Genus EVO – compact condensing, ultra-slim design. Widely used in homes with limited space in technical cabinets.
  • Cares Premium – condensation with integrated Wi-Fi connectivity and Ariston Net smart thermostat included.

Standard boilers

  • Egis Plus - Wall-mounted forced draught boiler, standard range. Widely used in Madrid from 1995 to 2015. Many still in operation.
  • Alteas – Combi boiler with integrated 40 L tank. For homes with high DHW demand.
  • Microgenus Plus – compact combi boiler, forced draught. Common in small-sized refurbished apartments.

Most common fault codes

Ariston boilers display numerical codes on the screen. The most common ones in the Madrid area:

CodeMeaningCommon cause
101Low pressureWater below 0.5 bar: refill the circuit or repair the leak
102DHW NTC sensor out of rangeDefective domestic hot water sensor
103NTC CH sensor out of rangeHeating sensor (flow) fault
104Flue gas NTC sensor out of rangeDefective flue gas sensor
108OvertemperatureTemperature exceeded: circulating pump or NTC
201Fan faultExtractor motor blocked or lack of voltage
501Ignition faultNo flame after 3 attempts: gas, electrode, or PCB

Ariston spare parts: own stock and 24-hour delivery

We maintain stock of the most requested Ariston spare parts. Parts located and shipped in 24-48 hours to all of Spain:

  • PCBs (Egis Plus, Clas EVO, Genus EVO)
  • Circulator pumps and hydraulic groups
  • NTC sensors for heating, DHW, and flue gases
  • Gas valves and micro pressure switches
  • Extractors and fans
  • Primary and plate heat exchangers
  • Ignition and ionisation electrodes
View Ariston spare parts catalogue

Frequently Asked Questions about Ariston Boilers

The most frequently asked questions we receive about Ariston boilers:

Yes. The Ariston Thermo Group manufactures both gas and condensing boilers as well as electric water heaters, electric water heaters, heat pumps, and solar thermal energy solutions. In Spain, Ariston water heaters are well known. Our service covers Ariston gas boilers. For electric water heaters, contact us to assess the intervention.

Fault code 501 indicates ignition fault with safety lockout. The boiler did not detect a flame after several attempts. Check that the gas is open. If it is open, common causes are: dirty or worn ignition electrode, faulty gas valve, or PCB issues. Reset with the reset button and if it recurs in 1-2 cycles, call a technician.

The Egis Plus is a very robust model with a good track record. With annual maintenance, it can last 15-22 yearsIn Madrid, there are many units in operation that are over 18 years old. The most common faults after 10-12 years are the circulating pump, the plate heat exchanger (due to limescale), and the 3-way valve.

Fault code 101 indicates insufficient pressure (less than 0.5 bar). If it repeatedly drops even after refilling the circuit, there is a leak somewhere: it could be internal (seal inside the boiler), in the expansion vessel (depleted), or in a connection of the radiators. Do not repeatedly refill without locating the source, as it may damage the boiler in the long term.

If the standard boiler is over 15 years old or has recurring faults, switching to a condensing boiler (Clas EVO, Genus EVO) can result in a 25-30% gas saving, recovering the investment in 5-7 years in Madrid. For equipment in good condition and less than 10 years old, repair is more economical. We guide you before deciding.

The rating plate It is inside the front cover or at the bottom of the body. It includes the model, the power in kW, and the serial number. If the plate is damaged or illegible, send us a photo of the equipment by contact and we help you identify it to locate the correct spare parts.


Does your Ariston boiler need servicing?

Indicate the model and the fault code. We will guide you before the visit.