Fagor (Mondragón Corporation) • Founded 1956 • Basque Country, Spain
Repair and spare parts for Fagor boilers in Madrid
Specialised technical service for Fagor boilers in Madrid. Although the brand ceased production in 2013, we repair and locate spare parts for the FE, FEV, and FEB series still in operation.
💡 Direct response
Fagor was a Spanish brand of boilers belonging to the Mondragón Corporation (Basque Country), founded in 1956. After the bankruptcy of Fagor Electrodomésticos in 2013, the production of boilers ceased. However, their FE and FEV forced draught models remain very numerous in the housing stock of Madrid, and many can be repaired with compatible spare parts or existing stock.
🔌 Historic Spanish brand
The most installed brand in Spanish homes until 2013. Thousands of units still in operation in Madrid.
📦 Available stock
PCBs, pumps, and sensors for FE-24, FEB-24, FEV. Own stock and approved equivalents.
🔥 Honest advice
If the part is not available, we recommend the best replacement option. No tricks.
Most common Fagor models in Madrid
- FE-24 / FE-20 N - Sealed forced draft combi boiler. The most installed model in Madrid until 2013.
- FEB-24 / FEB-20 – Forced draft twin-pipe boiler. Widely used in residential blocks.
- FEV-24 – High-power combi boiler for large homes.
- FE-24E N - version with electronic ignition. Very common in renovations 2005-2013.
- FEE (series) – heating-only boiler, for homes with independent DHW.
Most common fault codes
| Code | Meaning | Common cause |
|---|---|---|
| E1 | Ignition fault | No flame after 3 attempts: gas, electrode, or valve |
| E2 | Overtemperature | Temperature exceeded: pump or limit thermostat |
| E3 | Heating NTC sensor | Defective flow temperature sensor |
| E4 | DHW NTC sensor | Domestic hot water sensor faulty |
| E5 | Fan fault | Extractor fan motor stopped or pressure switch sensor |
| E6 | Spontaneous flame | Defective gas valve or ionisation electrode |
Fagor spare parts available
We maintain stock of the most requested spare parts and source distributor parts when possible:
- PCB control boards for FE-24 and FEB-24
- Circulator pumps (direct and equivalents)
- NTC sensors for heating and DHW
- Ignition and ionisation electrodes
- SIT gas valves and equivalents
- Extractors and fans
- Gaskets and maintenance kits
Frequently Asked Questions about Fagor Boilers
Yes, in many cases. The FE-24 and FEB-24 models have good availability of spare parts in the distribution market, and many components are equivalent to other brands (SIT gas valves, Honeywell PCBs, Grundfos pumps). However, for very specific models or those prior to 2005, the availability of the original PCB may be limited. We assess before quoting.
If the boiler is more than 15 years old and the fault is severe (PCB, heat exchanger), it is usually more cost-effective to replace it with a new condensing one. The annual gas savings can be 25-30%. For minor faults (pump, NTC, electrode), repair is still cost-effective in most cases.
E1 indicates a ignition fault with safety lockout. The boiler attempted to ignite several times without detecting a flame. Check that the gas is open. The reset is done by turning the boiler off and on or pressing the reset button if it has one. If the error repeats in the first cycles, technical intervention is required.
Yes. All the spare parts we install come with a manufacturer's warranty (3 months to 2 years depending on the part) and our labour warranty. For equivalent parts (non-original), we apply the same performance warranty as for original parts.
Does your Fagor boiler need servicing or repair?
Indicate the model and the fault code. We will guide you before the visit.