Vaillant ecoTEC exclusive VMW 43CF/1-7 SfI boiler
Heating and hot water for everyday use, combined in a gas boiler.
- Gas
- Natural gas Without conversion to LPG
- Wi-Fi
- Included myVAILLANT
- Heating
- 4.2-33.2 kW 80/60 °C
- Domestic hot water flow rate
- 20.4 l/min ΔT 30 K
Gas and Wi-Fi: compatibility and accessories
Gas and conversion: This version is documented for natural gas. Conversion to propane and compatibility with butane are not offered. Source 1 ↗ Source 2 ↗ Source 3 ↗
Wi-Fi and supply: The exact commercial sheet of ecoTEC exclusive VMW 30CF, 36CF, and 43CF indicates sensoCOMFORT radio and myVAILLANT connectivity as standard. The gas category of these Spanish versions is I2H. Source 1 ↗ Source 2 ↗ Source 3 ↗
Description
Vaillant combines home heating and hot water for taps and showers. When choosing it, both water usage and heating needs are important: a home with multiple showers running at the same time requires a different assessment.
Its micro-accumulation system helps to have hot water ready for everyday use. It is not equivalent to a large tank: the choice should take into account the flow rate you need and how many taps or showers you will use at the same time.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data of Vaillant ecoTEC exclusive VMW 43CF/1-7 SfI
- Brand
- Vaillant
- Model
- Vaillant ecoTEC exclusive VMW 43CF/1-7 SfI boiler
- Status
- New
- Supply scope
- With sensoCOMFORT radio and myVaillant. Installation not included.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
- Commercial reference
- 125834629
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Heating power G20 (80/60 °C)
- 4.2-33.2 kW
Heating - Heating power G20 (50/30 °C)
- 4.9-36.0 kW
Heating - Heating thermal load G20 (Hi)
- 4.5-34.2 kW
Heating - Adjustable flow temperature
- 30-80 °C
Heating - Maximum heating pressure
- 3 bar
Heating - Maximum power DHW G20
- 42.8 kW
Hot water - Nominal thermal load DHW G20 (Hi)
- 40.0 kW
Hot water - Specific flow rate D (ΔT 30 K, EN 13203-1)
- 20.4 l/min
Hot water - Declared domestic hot water flow rate (ΔT 25 K)
- 24.5 l/min
Hot water - Minimum starting flow rate
- 2.0 l/min
Hot water - Domestic hot water flow limiter
- 14.0 l/min
Hot water - Adjustable domestic hot water temperature
- 35-65 °C
Hot water - Allowed service pressure for domestic hot water
- 0.3-10 bar
Hot water - Required connection pressure for domestic hot water
- 0.7 bar
Hot water - Hot water system
- Mixed with micro-accumulation
Hot water - Dimensions (height x width x depth)
- 720 x 440 x 450 mm
Dimensions and installation - Net weight
- 46 kg
Dimensions and installation - Minimum lateral distance
- 5 mm on each side
Dimensions and installation - Minimum inferior distance
- 180 mm
Dimensions and installation - Minimum front service distance
- 500 mm
Dimensions and installation - Distance greater with duct 60/100
- 165 or 248 mm, according to the installation plan
Dimensions and installation - Maximum distance with duct 80/80
- 220 mm
Dimensions and installation - Maximum distance with duct 80/125
- 276 mm
Dimensions and installation - Natural gas connection pressure G20
- 20 mbar
Gas and connections - Gas connection on the appliance
- 20 mm
Gas and connections - Air connection and exhaust in the appliance
- 80/125 mm
Gas and connections - NOx emissions class
- 6
Gas and connections - Maximum electrical consumption in heating
- 105 W
Electricity - Maximum electrical consumption in domestic hot water
- 122 W
Electricity - Nominal power supply
- 230 V / 50 Hz
Electricity - Standby power consumption
- Less than 2 W
Electricity - Degree of protection
- IPX5D
Electricity
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- ecoTEC exclusive VMW installation manualPDF · 88 pages · VaillantView original on the manufacturer's website ↗
- ecoTEC exclusive technical sheetPDF · 2 pages · VaillantView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.