Vaillant ecoTEC Pure VMW286/7-2 HES boiler
Heating and hot water for everyday use, combined in a gas boiler.
- Gas
- Natural gas Convertible to propane
- Wi-Fi
- Optional myVAILLANT + control
- Heating
- 7.5-24.0 kW 80/60 °C
- Domestic hot water flow rate
- 13.5 l/min ΔT 30 K
Gas and Wi-Fi: compatibility and accessories
Gas and conversion: Natural gas G20 supply; adaptation to propane G31 with the kit and adjustments indicated by the manufacturer. Compatibility with butane G30 is not offered without explicit documentation for this version. The conversion and commissioning are the responsibility of a qualified professional; they are not included in the purchase. Source 1 ↗ Source 2 ↗
Wi-Fi and supply: Connectable with a VRT 50/2 control, sensoHOME or sensoCOMFORT plus the myVAILLANT module. Connection accessories are not assumed to be included. Source 1 ↗ Source 2 ↗
Description
Vaillant combines home heating and hot water for taps and showers. When choosing it, both water usage and heating needs are important: a home with multiple showers running at the same time requires a different assessment.
Domestic hot water is prepared when you turn on the tap, without an integrated storage tank. It is important to check how many water points you will use at the same time and the available space to replace the boiler.
What to check before installing this boiler
The choice of equipment does not replace the inspection of the installation by a qualified professional.
- Confirm the model and commercial reference, the type of gas, and the supply configuration in the manufacturer's documentation.
- Ask a qualified installer to assess the heating and domestic hot water demand; compare measured flow rates at the same temperature difference.
- Check dimensions, connections, flue gas evacuation, condensate drainage, and controls compatible with the existing installation.
- Confirm the included accessories and the delivery time before scheduling the installation. The online purchase of the equipment does not include installation or commissioning.
Technical data of Vaillant ecoTEC Pure VMW286/7-2 HES boiler
- Brand
- Vaillant
- Model
- Vaillant ecoTEC Pure VMW286/7-2 HES boiler
- Status
- New
- Supply scope
- Equipment without installation; please confirm the accessories for this configuration.
- Shipping
- Included in mainland Spain. Please confirm the deadline.
Specifications and dimensions of the model
Compare each magnitude under its testing conditions: heating, domestic hot water, efficiency, and dimensions.
- Heating power G20 (80/60 °C)
- 7.5-24.0 kW
Heating - Heating power G20 (50/30 °C)
- 8.3-26.1 kW
Heating - Heating load G20
- 7.8-24.8 kW
Heating - Adjustable flow temperature
- 30-80 °C
Heating - Maximum heating pressure
- 3 bar
Heating - Nominal heating flow rate (ΔT 20 K)
- 1.033 l/h
Heating - Heating expansion vessel
- 8 l
Heating - Domestic hot water power G20
- 7.7-28.0 kW
Hot water - Maximum thermal load DHW G20
- 28.6 kW
Hot water - Specific flow rate D (ΔT 30 K, EN 13203)
- 13.5 l/min
Hot water - Specific flow rate for domestic hot water (ΔT 35 K)
- 11.6 l/min
Hot water - Declared instantaneous flow rate for domestic hot water (ΔT 25 K)
- 16.2 l/min
Hot water - Minimum water flow
- 1.7 l/min
Hot water - Cold water flow limiter
- 14 l/min
Hot water - Adjustable domestic hot water temperature
- 35-60 °C
Hot water - Allowed service pressure for domestic hot water
- 0.3-10 bar
Hot water - Preparation of domestic hot water
- Deactivatable preheating
Hot water - Dimensions (height x width x depth)
- 720 x 440 x 338 mm
Dimensions and installation - Net weight
- 30.8 kg
Dimensions and installation - Minimum lateral distance
- 5 mm on each side
Dimensions and installation - Minimum inferior distance
- 180 mm
Dimensions and installation - Front service distance
- 500 mm
Dimensions and installation - Distance greater with duct 60/100
- 165 mm
Dimensions and installation - Maximum distance with duct 80/125
- 275 mm
Dimensions and installation - Maximum distance with duct 80/80
- 300 mm
Dimensions and installation - Gas supply pressure G20
- 20 mbar
Gas and equipment - NOx emissions class
- 6
Gas and equipment - Electrical supply
- 230 V / 50 Hz
Electricity and acoustics - Maximum electrical consumption
- 110 W
Electricity and acoustics - Standby power consumption
- 1.8 W
Electricity and acoustics - Degree of protection
- IPX4D
Electricity and acoustics - Interior acoustic power LWA
- 52 dB(A)
Electricity and acoustics - Energy class heating / DHW and profile
- A / A, XL profile
Efficiency and construction - Primary heat exchanger
- Stainless steel
Efficiency and construction
PDF and documentation of the model
Original documents, unmodified. Refer to the installation plan and the conditions of each data point before selecting the equipment.
- Installation manual ecoTEC pure VMW 236 and 286PDF · 48 pages · VaillantView original on the manufacturer's website ↗
- ecoTEC pure catalog and technical sheetPDF · 6 pages · VaillantView original on the manufacturer's website ↗
The gallery sheets are summaries of Uniclima based on these documents. The external volume diagram does not represent connections, accessories, or service distances.