Fault Codes for Ferroli Divatech D F24/F32: Meaning and Solution

Caldera Ferroli Divatech D F24/F32 montada en un loft de estilo industrial.
Ferroli Divatech D F24/F32
Briefly: The Ferroli Divatech D F24/F32 boiler displays fault codes to indicate issues. For example, code A01 means the burner does not ignite, while F37 indicates low water pressure. Refer to the guide for detailed solutions.

Short answer

The Ferroli Divatech D (F24/F32) displays its faults with codes on the screen: those starting with A are lockouts that usually require a reset and those that start with F They are anomalies of sensors, pressure, or electrical network. In this guide, you have the meaning of each code, why it appears, and how to solve it, as well as the exact spare part when the fault corresponds to a specific component. The Divatech shares the diagnostic platform of Ferroli's domestic range.

Ferroli Divatech D F24/F32 boiler with the list of fault codes and their solution

Fault code table for the Divatech D F24/F32

Quick summary of all fault codes. Below you have the details of each one with its cause and solution.

CodeMeaning
A01The burner does not ignite (ignition lockout)
A02Call present with the burner off
A03Overtemperature protection operation
A06Lack of flame after the ignition phase
F04Flue thermostat anomaly
F05The air pressure switch does not close contacts after the fan starts.
F10Heating sensor anomaly
F34Supply voltage below 170 V
F35Abnormal electrical grid frequency
F37Water pressure in the system too low
F39Outdoor sensor anomaly
F40Water pressure in the system too high
F47Water pressure transducer anomaly

What can you check yourself?

Primer plano del manómetro en la caldera Ferroli Divatech D F24/F32.
Ferroli Divatech D F24/F32

Some alerts can be resolved with simple and safe checks: replenishing the water pressure, bleeding the air from the radiators, checking that the gas valve is open, or resetting the boiler after a temporary lockout. If the code reappears after doing this, there is an underlying cause that should be reviewed by a qualified technician. Do not manipulate internal gas components nor electronics.

How to replenish the pressure step by step

  1. Locate the filling valve under the boiler.
  2. Open it slowly while observing the pressure gauge.
  3. Close the valve upon arrival at between 1 and 1.5 bar in cold.
  4. Bleed the radiators starting with the furthest one and check the pressure again.
  5. Reset the boiler; if the pressure warning disappears, the problem was resolved.

All fault codes and their solution

A01 — The burner does not ignite (ignition lockout)

Why does it appear: Gas shortage, gas valve closed, ignition or detection electrode dirty or poorly positioned, defective gas valve, or ignition power too low.

What to do: Check that the gas valve is open and that there is a supply, and reset the boiler. If the lockout repeats, a technician should inspect it: electrodes, wiring, and gas valve.

Related spare part: Gas valve

A02 — Flame present with burner off

Why does it appear: Anomaly of the detection or ionization electrode, or of the PCB, which reads a flame that does not actually exist.

What to do: Requires technical inspection of the ionisation electrode, its wiring, and the control board.

Related spare part: PCB (control board)

A03 — Overtemperature protection activation

Why does it appear: The heating sensor detects an excessive temperature: lack of water circulation, blocked pump, air in the system, or damaged sensor.

What to do: Check the pressure and bleed the air from the radiators. If it persists, the circulation pump and the heating sensor need to be checked.

Related spare part: Circulation pump

A06 — Lack of flame after the ignition phase

Why does it appear: The flame repeatedly goes out after ignition. This is usually due to low gas pressure, a faulty detection electrode, or poor combustion.

What to do: Check the gas supply. The gas regulation and the detection electrode should be inspected by a technician.

Related spare part: Gas valve

F04 — Flue thermostat anomaly

Why does it appear: Poor flue gas evacuation, obstructed duct, or defective flue thermostat.

What to do: Never disable the flue thermostat: it protects against poor gas exhaust. The flue evacuation and the thermostat itself should be checked by a technician.

F05 — The air pressure switch does not close contacts after the fan starts

Why does it appear: Weak or faulty fan, pressure switch tube blocked or disconnected, flue blocked or defective air pressure switch.

What to do: Requires checking the fan, pressure tubes, and air pressure switch.

Related spare part: Pressure sensor / filling key

F10 — Heating sensor anomaly

Why does it appear: Flow sensor in short circuit or open circuit, or poor connection.

What to do: Check the wiring and, if necessary, replace the heating sensor.

Affected component: Temperature sensor

F34 — Supply voltage below 170 V

Why does it appear: Voltage drop in the electrical network or deficient electrical installation.

What to do: Check the mains voltage. It is an issue with the electrical installation, not the boiler.

Affected component: Electrical installation

F35 — Abnormal mains frequency

Why does it appear: Anomaly in the power supply network.

What to do: Check the electrical installation and the supply network.

Affected component: Electrical installation

F37 — Water pressure in the system too low

Why does it appear: Water loss in the circuit, lack of filling, or defective water pressure switch.

What to do: Replenish the pressure to 1-1.5 bar when cold using the filling key. If it drops again and again, there is a leak that needs to be located.

Related spare part: Pressure sensor / filling key

F39 — External sensor anomaly

Why does it appear: External temperature sensor disconnected or faulty (if installed).

What to do: Check the external sensor and its wiring, or deactivate it in the parameters if it is no longer in use.

Affected component: Temperature sensor

F40 — Water pressure in the system too high

Why does it appear: Overfilling, expansion vessel without air pressure, or faulty safety valve.

What to do: Reduce the pressure by bleeding a radiator until it reaches 1-1.5 bar when cold. If it rises on its own, the expansion vessel needs to be checked.

Related spare part: Pressure sensor / filling key

F47 — Water pressure transducer anomaly

Why does it appear: Water pressure sensor or pressure switch faulty or poorly connected.

What to do: Check the wiring and replace the water pressure sensor or pressure switch if it is defective.

Related spare part: Pressure sensor / filling key

When to call a technician

Técnico ajustando la caldera Ferroli Divatech D F24/F32.
Ferroli Divatech D F24/F32

Fault codes related to sensors, electronics, gas valve, fan, or flue gas evacuation require a qualified technician with the appropriate equipment. If the same fault code reappears after a reset, or if the pressure drops repeatedly, a professional inspection is advisable. In Uniclima do you find spare parts for this boiler.

Frequently Asked Questions

The burner does not ignite. This is usually due to a lack of gas, a closed gas valve, or a dirty ignition electrode. After checking the gas, you can reset; if it repeats, the electrodes and gas valve need to be checked.

The A03 is an overtemperature protection, usually due to lack of water circulation (low pressure, air in the circuit, or blocked pump). Check the pressure and bleed the radiators; if it repeats, check the pump and the heating sensor.

With the function control or the reset button on the panel. If the code reappears after resetting, do not insist: it indicates a fault that should be checked by a qualified technician.