Fagor Natur FC 24 24 N Fan Ref. MUC080060

Fagor Natur FC 24 24 N Fan Ref. MUC080060

Stock · 3 units

Extractor: refurbished spare part that evacuates combustion gases with forced draft. Useful if it doesn't start due to draft failure, makes noise, or doesn't spin. Compatible with Natur FC 24-24 N (ref. MUC080060). Includes a one-year warranty. Delivery time and cost are shown at checkout for the destination country.

VAT included

Compatibility

Fagor boilers compatible with reference MUC080060

Extractor with reference MUC080060. A proven compatibility: Natur FC 24-24 N.

Proven compatibility

Boiler modelFamilyVerification
Fagor Natur FC 24-24 NFagor Natur FC (condensation)Contrasted

Can't see your model or have questions? The printed reference takes precedence. How to check it ·

Guide

How to check if the part MUC080060 is the one for your boiler

What determines it is not the boiler model, but the reference printed on the part you already have installed.

  1. Find the reference printed on the installed part and check whether it matches the catalogue reference MUC080060. If it is not visible, do not identify the part from its shape alone.
  2. Check the full boiler model on its data plate and look for it in the model associations on this page.
  3. Compare the connections and physical body with the original part before installation.
  4. If anything is unclear, send us a photo of the marking via WhatsApp before placing your order.
Diagnosis and fault codes

Symptoms and faults that the extractor MUC080060 resolves.

The extractor evacuates the combustion gases with forced draft. These are the typical symptoms and what to do:

Fault codes for Fagor that this part resolves.

CodeFaultDiagnosis and solution
E8Defective fanThe MUC080060 extractor does not start or its speed is inconsistent; the electronics detect absence/incorrect rpm reading and lock with E8. Check the fan power supply and wiring and verify the nF (rpm) reading in diagnostics; if it does not spin or the reading is incorrect, replace it.

These symptoms can have more than one cause. If your boiler displays a fault code, send it to us via WhatsApp along with a photo of the labeling, and we'll tell you if this is the part.

Technical data

Data sheet for the Fagor MUC080060 extractor.

Catalogue reference
MUC080060
Brand
Fagor
Type of part
Extractor fans
Units in stock
3 units
Status
Refurbished
Warranty
1 year
Shipping
Delivery time shown at checkout
Return
14 days
Frequently Asked Questions

Frequently asked questions about the MUC080060 extractor

What does it do?
The extractor/fan evacuates the combustion gases (forced draught).
Does it not start due to a draught fault, make noise, or not spin?
Seized, noisy, or unpowered fan.
Which models is it suitable for?
Part shared by various models (see Compatibility). If your model does not appear, send us a photo of the marking and we will confirm it.
Installation and recommendations
Check the connector, the 230 V power supply, and free rotation.
What does refurbished mean and what coverage does it have?
Part dismantled from an out-of-service boiler, inspected and tested. Includes 1-year warranty and 14-day return policy. Shipping 24/48 h within the peninsula.

Spare parts related to Fagor Fagor Natur FC (condensing)

Entrega calculada por destinoDelivery time shown at checkout
1-year warrantyreviewed and tested
14-day returnuninstalled parts
Technical supportwe verify your model
Fagor Natur FC 24 24 N Fan Ref. MUC080060